Figure 56: Mounting Bracket for Wall and Pole Mounting AP with Power Supply
One of four keyhole slots to mount the AP.
1
Three of six bracket mount holes for fastening the bracket to a wall. Support bolts of up to 0.25 inch
(6 mm) in diameter
2
Screw holes for fastening the power supply to the bracket
3
Before you begin
Ensure that you have the following materials before beginning to mount the AP to a wall:
Table 5: Materials Required to Mount AP to a Wall using AIR-MNT-VERT2= Kit
Supplied in the
Kit?
Materials Required
Yes
Ground lug and screws (provided with the access point)
Yes
Wall Mount Bracket
Yes
Four M6 x 12-mm Hex-head Bolts
Yes
Four #8-32 screws to mount the power supply
No
Crimping tool for ground lug, Panduit CT-720 with CD-720-1 die
No
Four wall mounting screws
No
#6 AWG ground wire
No
Shielded outdoor-rated Ethernet (CAT5e or better) cable
No
Grounding block
Cisco Catalyst 9124AX Series Outdoor Access Point Hardware Installation Guide
45
Installation Overview
Vertically Mounting the AP with DC Supply to a Wall