Table 1: C3850-NM-4-1G Module
Action
Interface
Configure this interface
GigabitEthernet1/1/1
Configure this interface
GigabitEthernet1/1/2
Configure this interface
GigabitEthernet1/1/3
Configure this interface
GigabitEthernet1/1/4
Disregard
TenGigabitEthernet1/1/1
Disregard
TenGigabitEthernet1/1/2
Disregard
TenGigabitEthernet1/1/3
Disregard
TenGigabitEthernet1/1/4
C3850-NM-4-10G Module
All ports in the C3850-NM-4-10G module default to 10 G and should be configured as TenGigabitEthernet1/1/1
through TenGigabitEthernet1/1/4, even when you are operating them as 1 G using SFPs. Only four interfaces
are valid; the other four should not be used even though they still show up in the CLI.
Table 2: C3850-NM-4-10G Module
Action
Interface
Disregard
GigabitEthernet1/1/1
Disregard
GigabitEthernet1/1/2
Disregard
GigabitEthernet1/1/3
Disregard
GigabitEthernet1/1/4
Configure this interface
TenGigabitEthernet1/1/1
Configure this interface
TenGigabitEthernet1/1/2
Configure this interface
TenGigabitEthernet1/1/3
Configure this interface
TenGigabitEthernet1/1/4
Catalyst 3850 Switch Hardware Installation Guide
10
OL-26779-05
Installing a Network Module
Network Module Port Configurations