Table 1: C3850-NM-4-1G Module

Action

Interface

Configure this interface

GigabitEthernet1/1/1

Configure this interface

GigabitEthernet1/1/2

Configure this interface

GigabitEthernet1/1/3

Configure this interface

GigabitEthernet1/1/4

Disregard

TenGigabitEthernet1/1/1

Disregard

TenGigabitEthernet1/1/2

Disregard

TenGigabitEthernet1/1/3

Disregard

TenGigabitEthernet1/1/4

C3850-NM-4-10G Module

All ports in the C3850-NM-4-10G module default to 10 G and should be configured as TenGigabitEthernet1/1/1
through TenGigabitEthernet1/1/4, even when you are operating them as 1 G using SFPs. Only four interfaces
are valid; the other four should not be used even though they still show up in the CLI.

Table 2: C3850-NM-4-10G Module

Action

Interface

Disregard

GigabitEthernet1/1/1

Disregard

GigabitEthernet1/1/2

Disregard

GigabitEthernet1/1/3

Disregard

GigabitEthernet1/1/4

Configure this interface

TenGigabitEthernet1/1/1

Configure this interface

TenGigabitEthernet1/1/2

Configure this interface

TenGigabitEthernet1/1/3

Configure this interface

TenGigabitEthernet1/1/4

   Catalyst 3850 Switch Hardware Installation Guide

10

OL-26779-05   

Installing a Network Module

Network Module Port Configurations

Содержание C3850-NM-4-1G

Страница 1: ...ription Network Module 1 This module has four 1 G SFP module slots Any combination of standard SFP modules are supported SFP modules are not supported If you insert an SFP module in the 1 G network module the SFP module does not operate and the switch logs an error message This is supported on the following switch models Note WS C3850 24T P U WS C3850 48T F P U WS C3850 12X48U WS C3850 24XU WS C38...

Страница 2: ...itch models Note WS C3850 48T F P U WS C3850 12X48U WS C3850 24XU WS C3850 12XS WS C3850 24XS C3850 NM 4 10G This module has eight 10 G slots with an SFP port in each slot Each port supports a 1 G or 10 G connection This is supported on the following switch models Note WS C3850 12X48U WS C3850 24XU WS C3850 24XS C3850 NM 8 10G This module has two 40 G slots with a QSFP connector in each slot This ...

Страница 3: ...etwork modules are hot swappable Figure 1 C3850 NM 4 1G Network Module LEDs 3 Captive screws 1 1 G Ethernet SFP slots 2 Figure 2 C3850 NM 2 10G Network Module 1 G Ethernet SFP slots 3 Captive screws 1 LEDs 4 1 G or 10 G Ethernet SFP slots 2 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 3 Installing a Network Module Network Module Overview ...

Страница 4: ...k Module LEDs 3 Captive screw This network module has only one screw You must fasten the screw completely to secure the module and loosen the screw first so that the module may be removed Note 1 10 G or 1 G SFP slots 2 Catalyst 3850 Switch Hardware Installation Guide 4 OL 26779 05 Installing a Network Module Network Module Overview ...

Страница 5: ...ork Module LEDs 3 Captive screws 1 40 G QSFP slots 2 Figure 6 Blank Network Module Captive screws 2 Blank module 1 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 5 Installing a Network Module Network Module Overview ...

Страница 6: ...k is off due to a fault or because it has exceeded a limit set in the switch software Link faults occur when noncompliant cabling is connected to an SFP SFP port Use only standard compliant cabling to connect to Cisco SFP SFP ports You must remove from the network any cable or device that causes a link fault Caution Blinking amber Link for the SFP SFP has been disabled Amber Catalyst 3850 Switch H...

Страница 7: ...06 Warning Equipment That You Need Ratcheting torque screwdriver with a number 2 Phillips head that exerts up to 15 pound force inches lbf in of pressure Panduit crimping tool with optional controlled cycle mechanism model CT 720 CT 920 CT 920CH CT 930 or CT 940CH Wire stripping tools 12 gauge copper ground wire insulated or not for the single hole ground connection 8 gauge copper ground wire insu...

Страница 8: ...fiber optic cable until you connect the cable The plugs and caps protect the module ports and cables from contamination and ambient light Removing and installing a network module can shorten its useful life Do not remove and insert a network module more often than is necessary To prevent ESD damage follow your normal board and component handling procedures when connecting cables to the switch and ...

Страница 9: ...e rightmost tab 2 You will feel some light resistance because a spring loaded tab inside the slot will push back against the C3850 NM 8 10G module 3 Continue to tighten the jackscrew while gently pushing the front panel of the network module into the slot Network Module Port Configurations C3850 NM 4 1G Module All ports in the C3850 NM 4 1G module are natively GigabitEthernet and are configured Gi...

Страница 10: ...t1 1 1 through TenGigabitEthernet1 1 4 even when you are operating them as 1 G using SFPs Only four interfaces are valid the other four should not be used even though they still show up in the CLI Table 2 C3850 NM 4 10G Module Action Interface Disregard GigabitEthernet1 1 1 Disregard GigabitEthernet1 1 2 Disregard GigabitEthernet1 1 3 Disregard GigabitEthernet1 1 4 Configure this interface TenGiga...

Страница 11: ...rd TenGigabitEthernet1 1 1 Disregard TenGigabitEthernet1 1 2 Configure this interface even when operating as 1 G TenGigabitEthernet1 1 3 Configure this interface even when operating as 1 G TenGigabitEthernet1 1 4 C3850 NM 8 10G Module All ports in the C3850 NM 8 10G module default to 10 G and should be configured as TenGigabitEthernet1 1 1 through TenGigabitEthernet1 1 8 even when you are operatin...

Страница 12: ...FortyGigabitEthernet1 1 1 Configure this interface FortyGigabitEthernet1 1 2 Disregard TenGigabitEthernet1 1 1 Disregard TenGigabitEthernet1 1 2 Disregard TenGigabitEthernet1 1 3 Disregard TenGigabitEthernet1 1 4 Disregard TenGigabitEthernet1 1 5 Disregard TenGigabitEthernet1 1 6 Disregard TenGigabitEthernet1 1 7 Disregard TenGigabitEthernet1 1 8 If you use a 4x10G breakout cable the ports default...

Страница 13: ...s between the online insertion and removal OIR of network modules Note Procedure Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Do not remove the network module with connected cables or installed SFP modules Always remove any cables and modules before you remove the network module Caution A module interface might become error disabled when a network module...

Страница 14: ...ported SFP modules on the switch For the latest information about supported SFP and SFP modules refer to the Cisco Transceiver Modules Compatibility Information at http www cisco com en US products hw modules ps5455 products_device_support_tables_list html For information about installing removing cabling and troubleshooting SFP modules see the module documentation that shipped with your device Ob...

Страница 15: ...ale clasp latch move it to the open unlocked position Step 4 Align the module in front of the slot opening and push until you feel the connector snap into place Figure 9 Installing an SFP Module in the Network Module Step 5 If the module has a bale clasp latch close it to lock the SFP module in place Step 6 Remove the SFP dust plugs and save Step 7 Connect the SFP cables Figure 10 Network Module w...

Страница 16: ...e out and down to eject the module If you cannot use your finger to open the latch use a small flat blade screwdriver or other long narrow instrument to open it Step 5 Grasp the SFP SFP module and carefully remove it from the slot Step 6 Place the SFP SFP module in an antistatic bag or other protective environment Finding the Network Module Serial Number If you contact Cisco Technical Assistance r...

Отзывы: