Routerare numbered from 0 to 3, right to left. When the system power is on, all fans should be operational.
However, the system continues to operate even if a fan fails.
Use the
show platform hardware slot slot fan status
command to view the status of the fans, for example:
Router#
show platform hardware slot P2 fan status
Fan group 1 speed: 60%
Fan 0: Normal
Fan 1: Normal
Fan 2: Normal
Fan 3: Fail
Reporting Functions
The chassis manager on the forwarding engine control processor manages the local resources of the forwarding
processor. The Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router display warning messages on
the console if the chassis interface-monitored parameters exceed a threshold. You can also retrieve and display
environmental status reports with the following commands:
•
show environment all
•
show version
•
show inventory
•
show platform
•
show platform software status control-processor
•
show diag
Parameters are measured and reporting functions are updated every 60 seconds. A brief description of each
of these commands follows.
show environment all Command
The
show environment all
command displays temperature, voltage, fan, and power supply information.
The following is sample output from the
show environment all
command.
Router#
show environment all
Sensor List:
Environmental Monitoring
Sensor
Location
State
Reading
Vin
P0
Normal
0 V AC
Iin
P0
Normal
0 A
Vout
P0
Normal
0 V DC
Iout
P0
Normal
1 A
Temp1
P0
Normal
18 Celsius
Temp2
P0
Normal
21 Celsius
Temp3
P0
Normal
24 Celsius
VPPB1: VX1
R0
Normal
1003 mV
VPPB1: VX2
R0
Normal
6937 mV
VPPB1: VX3
R0
Normal
758 mV
VPPB1: VX4
R0
Normal
1049 mV
VPPB1: VP1
R0
Normal
1784 mV
VPPB1: VP2
R0
Normal
1517 mV
VPPB1: VP3
R0
Normal
1510 mV
VPPB1: VP4
R0
Normal
5057 mV
VPPB1: VH
R0
Normal
11982 mV
VPPB2: VX2
R0
Normal
818 mV
VPPB2: VX3
R0
Normal
856 mV
VPPB2: VP2
R0
Normal
3312 mV
VPPB2: VH
R0
Normal
11977 mV
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide
88
Power Up and Initial Configuration
Reporting Functions