Approx.
Field Programmable
Time
Elapsed
Slot Card Type
Device : "ID-Name"
Needed
Time
State
==== =================== ================== ========== ========== ===========
0/1 SPA-8XCHT1/E1
2-I/O FPGA
00:01:00
00:00:23
Updating...
---- ------------------- ------------------ ----------- --------- -----------
0/2 SPA-2XT3/E3
4-T3 FPGA
--:--:--
--:--:--
Waiting...
==== =================== ====================================================
FPD Image Upgrade Examples
This section provides examples of automatic and manual FPD image upgrades. It includes the following
examples:
Automatic FPD Image Upgrade Example
The following example shows the output displayed when a SPA in slot 0 subslot 1 requires an FPD image
upgrade and the
upgrade fpd auto
command is
enabled
. The required FPD image is automatically upgraded.
*Nov 28 13:14:22.782: %FPD_MGMT-3-INCOMP_IMG_VER: Incompatible I/O FPGA (FPD ID=2) image
version detected for SPA-2XT3/E3 card in subslot 0/1. Detected version = 0.6, minimum
required version = 1.0. Current HW version = 1.0.
*Nov 28 13:14:22.783: %FPD_MGMT-5-UPGRADE_ATTEMPT: Attempting to automatically upgrade the
FPD image(s) for SPA-2XT3/E3 card in subslot 0/1. Use 'show upgrade fpd progress' command
to view the upgrade progress ...
*Nov 28 13:14:22.841: %FPD_MGMT-6-BUNDLE_DOWNLOAD: Downloading FPD image bundle for
SPA-2XT3/E3 card in subslot 0/1 ...
*Nov 28 13:14:22.981: %FPD_MGMT-6-UPGRADE_TIME: Estimated total FPD image upgrade time for
SPA-2XT3/E3 card in subslot 0/1 = 00:01:00.
*Nov 28 13:14:22.983: %FPD_MGMT-6-UPGRADE_START: I/O FPGA (FPD ID=2) image upgrade in
progress for SPA-2XT3/E3 card in subslot 0/1. Updating to version 1.1. PLEASE DO NOT INTERRUPT
DURING THE UPGRADE PROCESS (estimated upgrade completion time = 00:01:00) ...
*Nov 28 13:14:43.267: %FPD_MGMT-6-UPGRADE_PASSED: I/O FPGA (FPD ID=2) image in the SPA-2XT3/E3
card in subslot 0/1 has been successfully updated from version 0.6 to version 1.0. Upgrading
time = 00:00:20.285
*Nov 28 13:14:43.267: %FPD_MGMT-6-OVERALL_UPGRADE: All the attempts to upgrade the required
FPD images have been completed for SPA-2XT3/E3 card in subslot 0/1. Number of
successful/failure upgrade(s): 1/0.
*Nov 28 13:14:43.268: %FPD_MGMT-5-CARD_POWER_CYCLE: SPA-2XT3/E3 card in subslot 0/1 is being
power cycled for the FPD image upgrade to take effect.
Manual FPD Image Upgrade Example
In the following example, FPD for the 2-port T3/E3 SPA in subslot 0/3 is upgraded manually from the bundled
FPD image package file. The command excludes the
reload
option so the SPA does not automatically reload.
Router#upgrade hw-module subslot 0/3 fpd bundled
% The following FPD will be upgraded for SPA-2XT3/E3 (H/W ver = 1.1) in subslot 0/3:
================== =========== =========== ============
Field Programmable
Current
Upgrade
Estimated
Device: "ID-Name"
Version
Version
Upgrade Time
================== =========== =========== ============
2-I/O FPGA
1.0
1.1
00:01:00
================== =========== =========== ============
% NOTES:
- Use 'show upgrade fpd progress' command to view the progress of the FPD upgrade.
- You must reload the card after the upgrade. The FPD upgrade is not
finalized until
the card is reloaded.
- The output of 'show hw-module <target> fpd' will not reflect the upgraded FPD
version
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Software Configuration Guide, Cisco IOS
XE Everest 16.5
426
OL-14127-17
Upgrading Field-Programmable Devices
FPD Image Upgrade Examples