Environmental
Reporting
Features
System Environmenta
Reports
The
system
runs
routine
that
polls
the
ENVM
for
voltage
and temperature
readings
The system
obtains these
statistics
from
the
ENVM
at
rate
of
once
minute and
stores
them
in
buffer
You
can display the contents
of
this
buffer with
the
show
environment
command
The
resulting
display
contains the current intake
and
exhaust
air
temperatures
shutdown
thresholds
and
voltage
measurements
of
DC
lines Following
is
sample
output of the
show
environment
command
Router
ahow
environxaent
Environmental
controller firmware version
2.2
Serial number
is
00225259
calibrated
on
5-4093
by technician
mpo
Internal
temperature measured
27.0C
shuts
down
at
43.0C
Air
flow
appears
good
volt
line
measured
at
5.061V
12
volt
line
measured
at
12070V
-12
volt
line
measured
at
12.034V
-5 volt
line
measured
at
4.915V
Router
Automatic
Warning Messages
If
measurement
exceeds
desired
margins
but has not
exceeded
fatal
margins
warning message
is
printed
to
the system
console The
system
software
queries the
ENVM
for
measurements
once
minute
but warnings
for
given
test
point
are
printed
to
the screen
at
most
once
every
four
hours
If
measurement
exceeds
the desired margins
at
any time within
four-hour
period
an automatic
warning message
appears
on
the console
screen
As noted
the user
may
query
the
ENVM
using the
show
environment
command
at
any time
to
determine
if
measurement
is
at the
warning
level
Following
is
an
example
of
the
message
displayed
on
the
console
screen
when
measurement
has
exceeded
an acceptable
margin
Router
ENVIRONMENTAL
WARNING
Airflow
appears
marginal
Following
is
an
example
of
message
displayed
on
the console
screen
when
an ambient
temperature
measurement
has
exceeded
an acceptable
margin and
the
temperature
reading
is
given
Router
ENVIRONMENTAL
WARNING
Internal
temperature
measured
41.3C
Following
is
an
example
of
message
displayed
on
the console
screen
when
voltage
measurement
has
exceeded
an acceptable
margin and
the voltage reading
is
given
Router
ENVIRONMENTAL
WARNING
volt testpoint
measured
5.310V
Shutdown
Messages
and Threshods
The system
displays the following
type of
message
if
voltage or temperature
exceeds
maximum
or
fatal
thresholds
Router
SHUTDOWN
air
flow problem
If
test
point reaches
the
fatal threshold
the
ENYM
performs
as
follows
The
last
measured
values
from
each
of
the
six test
points
are
saved
to internal
NVRAM
The system
software
is
interrupted
and
shutdown message
is
displayed
on
the console
screen
The power
supply
is
shut off
after
few
milliseconds
of delay
4-4
AGS
Hardware
Installation
and Maintenance
Содержание AGS+
Страница 1: ...CISCO SYSTEMS ...
Страница 11: ...AGS Hardware Installation and Maintenance ...
Страница 17: ...Document Conventions xvi AGS Hardware Installation and Maintenance ...
Страница 27: ...Chassis Power Budget 1 10 AGS Hardware Installation and Maintenance ...
Страница 39: ...Chassis Components 2 12 AGS Hardware Installation and Maintenance ...
Страница 57: ...System Bootstrap Diagnostics 4 10 AGS Hardware Installation and Maintenance ...
Страница 83: ...Card Illustrations 5 26 AGS Hardware Installation and Maintenance ...
Страница 105: ...FOOl Optical Bypass Switch Pinout A 22 AGS Hardware Installation and Maintenance ...
Страница 121: ...Applique LED Indicators B lB AGS Hardware Installation and Maintenance ...
Страница 125: ...C 4 ACS Hardware Installation and Maintenance ...
Страница 127: ...Compliance Provisions D 2 AGS Hardware Installation and Maintenance ...
Страница 129: ...E 2 AGS Hardware Installation and Maintenance ...