Chapter 3 Troubleshooting
Diagnosing Problems
10/100 and 10/100/1000 Port Connections
A port appears to malfunction:
•
Verify the status of all ports. See
Table 1-7 on page 1-14
for descriptions of the LEDs and their
meanings.
•
Use the
show interfaces
privileged EXEC command to see if the port is error-disabled, disabled, or
shut down. Re-enable the port if necessary.
•
Verify the cable type. See
Appendix B, “Connector and Cable Specifications.”
10/100 PoE or PoE+ Port Connections
A powered device connected to a PoE or PoE+ port does not receive power:
•
Verify the status of all the ports. See
Table 1-7
for descriptions of the LEDs and their meanings.
•
Use the
show interfaces
privileged EXEC command to see if the port is error-disabled, disabled, or
shutdown. Re-enable the port if necessary.
•
Verify the cable type. Many legacy powered devices, including older Cisco IP phones and access
points that do not fully support 802.3af might not support PoE when connected to the switch by a
crossover cable. Replace the crossover cable with a straight-through cable.
Caution
Noncompliant cabling or powered devices can cause a PoE port fault. Use only compliant cabling to
connect Cisco prestandard IP Phones, and wireless access points, or 802.3af-compliant devices.
SFP Module
Use only Cisco SFP modules. Each Cisco module has an internal serial EEPROM that is encoded with
security information. This encoding verifies that the module meets the requirements for the switch.
•
Inspect the SFP module. Exchange the suspect module with a known good module.
•
Verify that the module is supported on this platform. (The switch release notes on Cisco.com list the
SFP modules that the switch supports.)
•
Use the
show interfaces
privileged EXEC command to see if the port or module is error-disabled,
disabled, or shutdown. Re-enable the port if needed.
•
Make sure that all fiber-optic connections are clean and securely connected.
Interface Settings
Verify that the interface is not disabled or powered off. If an interface is manually shut down on either
side of the link, it does not come up until you re-enable the interface. Use the
show interfaces
privileged
EXEC command to see if the interface is error-disabled, disabled, or shut down on either side of the
connection. If needed, re-enable the interface.
Ping End Device
Ping from the directly connected switch first, and then work your way back port by port, interface by
interface, trunk by trunk, until you find the source of the connectivity issue. Make sure that each switch
can identify the end device MAC address in its Content-Addressable Memory (CAM) table.