C-5
Catalyst 2950 Desktop Switch Hardware Installation Guide
78-11157-05
Appendix C Connecting to DC Power
Wiring the DC-Input Power Source
Figure C-3
Torquing Ground-Lug Screws
Wiring the DC-Input Power Source
Warning
Only trained and qualified personnel should be allowed to install or replace this
equipment.
Warning
Before performing any of the following procedures, ensure that power is
removed from the DC circuit. To ensure that all power is OFF, locate the circuit
breaker on the panel board that services the DC circuit, switch the circuit
breaker to the OFF position, and tape the switch handle of the circuit breaker in
the OFF position.
DC INPUT FO
R REMOTE
POWER SU
PPLY
SPECIFIED IN
MANUAL.
+12V @
4.5A
36 - 72V
1 - 0.5A
CONSOLE
A
B
65295
Torque to 15 lbf-in.