![Cisco 2948G - Catalyst Switch Скачать руководство пользователя страница 153](http://html.mh-extra.com/html/cisco/2948g-catalyst-switch/2948g-catalyst-switch_configuration-manual_67462153.webp)
7-57
Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide
—
Release 8.1
78-15486-01
Chapter 7 Configuring Spanning Tree
Configuring Spanning Tree BPDU Skewing
12 -
13 -
14 999
15 -
=======================================================================
Console> (enable)
Console> (enable) show spantree mst 3
Spanning tree mode MST
Instance 3
VLANs Mapped: 31-40
Designated Root 00-10-7b-bb-2f-00
Designated Root Priority 8195 (root priority:8192, sys ID ext:3)
Designated Root Cost 0 Remaining Hops 20
Designated Root Port 1/0
Bridge ID MAC ADDR 00-10-7b-bb-2f-00
Bridge ID Priority 8195 (bridge priority:8192, sys ID ext:3)
Port State Role Cost Prio Type
------------------------ ------------- ---- -------- ----
--------------------
6/1 forwarding BDRY 10000 30 P2P,
Boundary(PVST)
6/2 blocking BDRY 20000 32 P2P,
Boundary(PVST)
Console> (enable)
Configuring Spanning Tree BPDU Skewing
Commands that support the spanning tree BPDU skewing feature perform these functions:
•
Allow you to enable or disable BPDU skewing. The default is disabled.
•
Modify the show spantree summary output to show if the skew detection is enabled and for which
VLANs or PVST+ or MISTP instances the skew was detected.
•
Provide a display of the VLAN or PVST+ or MISTP instance and the port affected by the skew:
include this information:
–
The duration (in absolute time) of the last skew
–
The duration (in absolute time) of the worst skew
–
The date and time of the worst duration
To change how spanning tree performs BPDU skewing statistics gathering, enter the set spantree
bpdu-skewing command. The bpdu-skewing command is disabled by default.
To configure the BPDU skewing statistics gathering for a VLAN, perform this task in privileged mode:
Task
Command
Step 1
Configure BPDU skewing.
set spantree bpdu-skewing [enable | disable]
Step 2
Verify the configuration.
show spantree bpdu-skewing vlan [mod/port]