VCC-SXCXP3NIR
Rev.905-0133-00
©2018 CIS Corporation. All rights reserved.
8
□
3pin SIGNAL_OUT Circuit
Camera internal timing signals can be output. Please set the signal to be output from Line Source of Digital IO Control.
Please refer to the
, for the details.
・
5.0V CMOS logic level output
・
Output voltage Low: 0.55Vdc (Max), High: 3.8Vdc (Min)
□
5pin TRIGGER_IN
Circuit
Trigger signals can be input directly into the camera from external equipment. When you use this terminal, set
TriggerSource of Acquisition Control to LineIn. Please refer to the
, for the details.
・
5.0V, 3.3V CMOS level input (TTL compatible)
・
Input voltage Low: 0.5Vdc (Min), High: 2.1Vdc (Max)
6.
How to Save and Initialize the Settings
UserSets
UserSetSave
(Execute)
UserSetDefault
(Execute)
Settings shall be restored to the initial settings when UserSetDefault is executed. This can be done only when its Link
Configuration is CXP-1 (CxpLinkConfiguration). Unless otherwise UserSetSave is executed,
the settings would not be saved.
If you wish to save the setting values, execute UserSetSave. Doing so, the setting values are saved in the camera internal
ROM. And, the saved settings are reflected when the camera is turned on next time.
+5.0V
HD74LV1GT32ACME
1
2
3
4
5
SIGNAL_OUT
(CAMERA_INTERNAL)
HD74LV1GT14ACME
1
2
3
5
4
100
1K
+5.0V
(CAMERA_INTERNAL)
TRRIGER_IN