VCC-HD3N
Rev. 905-0160-01
©2018 CIS Corporation. All rights reserved.
23
1/1700
1/2000
1/2400
1/2800
1/3400
1/4000
1/4800
1/5600
1/6800
1/8000
1/9600
1/11200
1/13600
Top Menu
Setting Menu Selected Items
Explanation
Gain/Shutter/IRIS
Shutter Min
Limit
Same as
Shutter Value
To set the Minimum Shutter Limit when Shutter
Mode is at Auto.
※Note 1/※Note 2
Shutter Max
Limit
Same as
Shutter Value
To set the Maximum Shutter Limit when Shutter
Mode is at Auto.
※Note 1/※Note 2
Set Shutter
Limit
None
Push the CENTER button to settle the shutter limit.
When Max < Min is set, the setting will not be valid.
Iris Mode
Open
Set it to Open when DC Iris is not in use.
※Note 5
Auto
Iris Response
Speed
0: Low
To set the response speed of DC Iris when DC Iris is
set to Auto. When it is set to High, DC Iris
response speed becomes faster. And when it is set
to Low, DC Iris response speed becomes slower.
1: Mid
2: High
AE Speed
0~15
To set AE convergence speed.
ExpCompValue -18~0~18 [dB] To set Exposure Compensation Value.
Metering Mode
Average
To set metering mode.
Average: Averaging metering
Center Weighted: Center weighted metering
Spot: Spot metering
Backlight Compensation: Backlight compensation
metering
Center
Weighted
Spot
Backlight Comp
Spot Block X
0~15
To select the X coordinate value of the Left edge
Block of the metering area when Metering Mode is
set to “Spot”.
Spot Block Y
0~15
To select the Y coordinate value of the Top Block of
the metering area when Metering Mode is set to
“Spot”.
Spot Block W
1~16
To select the width (Block number) of the metering
area when Metering Mode is set to “Spot”.
Spot Block H
1~16
To select the height (Block number) of the metering
area when Metering Mode is set to “Spot”.