VCC-5CXP3NIR
Rev. 905-0123-00
©2018 CIS Corporation. All rights reserved.
24
9.4 Burst Mode
The start and stop of sequence operation are selectable from the edge control, level control, and register start of trigger
input signals.
・
Please set TriggerSelectorAndActivation to FrameBurstStart.
(1)
Edge Control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Effective Line
Effective Line
Effective Line
①
・
Sequence operation starts with a trigger input when SequencerActivation is set to FrameBurstStartEdge.
・
Exposure time for each frame (
①
) and output frame time (
②
) shall be controlled by the preset sequence parameter
set and the image size settings.
・
When the image output for the sequence loop count is completed, sequence operation ends.
(2)
High level control
TRIG IN
Video Out
Effective Line
Exposure
Effective Line
①
FVAL Out
②
Sequence Control Start
Sequence Control Finish
Sequence Control Stop
Sequence Control ReStart
Effective Line
Effective Line
Effective Line
①
When SequencerActivation is set to FrameBurstStartLevel, sequence operation is performed while the trigger input
is at High level.
・
Change the trigger input to Low level to stop operation in the middle. (If you wish to completely end the operation,
turn sequence control to OFF.)
・
Sequence operation restarts and operates continuously when the trigger input is changed to High level again.
・
When the image output for the sequence loop count is completed, sequence operation ends.
(3)
Register start
Sequence operation starts simultaneously when the SequencerActivation OFF is set to FrameBurstStartSoftware.