18
8.8
Test Pattern
ImageFormatControl
TestImageMode
OFF/ON
Test pattern can be output via the camera. This is useful to check if the system is operating properly.
8.9
LED Indicator
DeviceControl
DeviceIndicatorMode
Active
ErrorStatus
Inactive
・
Active
:
This is to indicate the communication status of CoaXPress.
・
ErrorStatus
:
Normally the light is OFF. However, the light turns ON when system error occurs.
・
Inactive
:
LED OFF
.
Please refer to the chart below for the lighting pattern at Active setting.
Lighting status
Camera Status
OFF
PoCXP No supply
Green
Slow blinking [0.5Hz]
Connection completed between device and host
Green
ON
Transmitting video data
Orange
Slow blinking [1Hz]
Waiting for a trigger input
Red
Fast blinking
System error occurred
※
The camera might work fine even when the red light is blinking. Also, please be noted that the camera would remain
indicating error, once the camera recognized an error, such as when a trigger was input in the restricted timing, or
when ROI or sub-sampling function was activated while grabbing images. Please reboot the camera, or execute
Device Control
– SensorReset to revert the camera to normal lighting condition.
Indicator LED