VCC-2CXP6R
Rev.905-0187-02
©2019 CIS Corporation. All rights reserved.
13
Acquisition Control
IllegalTriggerFlag
0 or 1
※
Since overlapping operation is invalid at CLK sync. trigger mode, the trigger at this timing shall
be masked
and “IllegalTriggerFlag” will not become “1”.
Device Control
ErrorFlagReset
Execute
This is to reset IllegalTriggerFlag to “0”.
5.8.
Fixed Trigger Shutter Mode (LineSync) H Sync. Trigger
(TriggerMode=On, TriggerSyncMode=LineSync, TriggerActivation= RisingEdge)
□
This is the mode to start exposure by the input trigger signals, and execute exposure for set period.
□
Trigger operation is H sync., V sync. reset. The delay time (Exposure Time Delay) from detecting the trigger edge in
the camera to actually starting exposure is 2H~3H. 1H jitter would occur to the Exposure Time Delay since the
external trigger signal shall synchronize with H inside the camera.
□
At least 1H or more pulse shall be input to the trigger. (Please refer to the table below for the 1 line width for each
mode.)
Video output
formt
CXP-3
BayerRG/Mono8
6.36
BayerRG/Mono10 7.81
BayerRG/Mono12 9.21
CXP-6
BayerRG/Mono8
3.18
BayerRG/Mono10 3.91
BayerRG/Mono12 4.61
Link rate
Time
for
1H
[us]
□
There is an exposure time period for approx. 4.997µs at the edge right after exposure time.
SP OUT
(Exposure Out)
Actual exposure period
Approx. 4.997us
□
The next trigger while outputting video for the prior trigger can be accepted. However, do not input a trigger
signal to start the next video outputting before completion of outputting the prior images.
Trigger input while exposure period (Exposure Time) shall be ignored in the camera. ((A) in the drawing next page.)
Please note that a trigger shorter than 1 frame cycle shall not be used.