VCC-16MV02
Rev.905-0163-00
©2018 CIS Corporation. All rights reserved.
31
12.
Factory Settings
Function
Address
Data
Camera Mode
1
1:
4tap Configuration mode
Output Data Selection
2
0:
8bit output
Trigger Shutter Mode
3
0:
Normal shutter mode (Free-run)
Trigger Polarity
4
0:
Positive
Trigger Input
5
0:
Camera Link CC1
FAST Trigger Mode Selection
6
0:
H Sync mode
Test Pattern Output
7
0:
OFF
Cursor Indication
8
0:
OFF
Horizontal Flip of the Output Image
11
0:
Normal
Vertical Flip of the Output Image
12
0:
Normal
Defective Pixel Correction
13
1:
ON
Serial Communication Baud Rate
14
0:
9600baud
Gain
20
0:
0dB
Shutter
23
0:
OFF
Gamma ON/OFF
40
0:
Through
Gamma coefficient Selection
41
4:
Gamma coefficient =0.5
Vertical Partial Mode
54
0:
OFF (3000line)
Factory setting for rear switch
Power Selection
SW1
CL side