VCC-16MV02
Rev.905-0163-00
©2018 CIS Corporation. All rights reserved.
12
User Data Settings
200
2 parameters
All 0xFF at
Ex-Factory.
Set any data for the user area (32 byte).
Save with SAVE command.
※
Do not set any address or data other than specified the above.
5.1.
The List of Preset Shutter
4096dot X 3000line
Data
2Tap mode
4Tap mode
8Tap mode 10Tap mode
0
1/14(OFF)
1/27(OFF)
1/54(OFF)
1/64(OFF)
1
1/60
1/60
1/60
↑
2
1/100
1/100
1/100
1/100
3
1/150
1/150
1/150
1/150
4
1/200
1/200
1/200
1/200
5
1/250
1/250
1/250
1/250
6
1/500
1/500
1/500
1/500
7
1/1000
1/1000
1/1000
1/1000
8
1/2000
1/2000
1/2000
1/2000
9
1/2500
1/2500
1/2500
1/2500
10
1/5000
1/5000
1/5000
1/5000
11
1/10000
1/10000
1/10000
1/10000
12
1/16000
1/20000
1/20000
1/20000
13
1/26000
1/26000
1/30000
1/29000
14
↑
1/38000
1/38000
1/40000
15
↑
↑
1/49000
1/51000
5.2.
Formula to Calculate Manual Shutter Values
Formula: Exposure Time = Time for 1 line (Please refer to the table below) x Address 24 set value + 14.26μs
Camera Mode
Time for 1 line
2Tap Configuration mode
24.512μs
4Tap Configuration mode
12.256μs
8Tap Configuration mode
6.128μs
10tap Configuration mode
5.185μs
※
The minimum setting value shall be 1 and the maximum setting value shall be clipped with 3000 or the total line number
for partial settings.