(n)
Using tensiometer, verify bridle cable tension forward of bridle cable clamps is
set to 25.0+2.0/-0.0 lb (11.3+0.9/-0.0 kg). If bridle cable tension falls outside spec-
ified tolerance, loosen forward clamp assembly and adjust bridle cable as
required to obtain 25.0+2.0/-0.0 lb (11.3+0.9/-0.0 kg).
(o)
Using scale, verify 20±1° rudder deflection angle.
(p)
Remove rigging lockout pin from rudder actuation pulley in empennage.
(q)
Ensure flight control systems operate through full range of travel without
binding, obstruction, or excessive friction.
(r)
Ensure bridle cable remains in capstan grooves during full rudder and yaw servo
travel and bridle cable moves freely through cable guards without chafing.
(s)
Ensure there is 0.005 inch (0.127 mm) minimum clearance between bridle cable
clamps along main control cable side.
(t)
Install access panel LE1, LE2 and RE2.
23 Dec 2016