C
HAPTER
22-10: GFC 700 A
UTOMATED
F
LIGHT
C
ONTROL
S
YSTEM
CIRRUS A
IRPLANE
M
AINTENANCE
M
ANUAL
M
AINTENANCE
P
RACTICES
MODELS SR22
AND
SR22T
18
C.
GSA 80 Servo Actuator
(1)
Removal - GSA 80 Servo Actuator
(a)
Set BAT 1, BAT 2, and AVIONICS switches to OFF positions.
(b)
Pull YAW SERVO circuit breaker.
(c)
(d)
Disconnect servo actuator connector from aircraft harness.
(e)
Remove bolts and washers securing servo actuator to servo mount.
(2)
Installation - GSA 80 Servo Actuator
(a)
Perform Inspection/Check - GSA 80 Servo Actuator.
(b)
Carefully align servo actuator with servo mount.
•
CAUTION
•
The servo actuator and servo mount must fit flush together
with no gaps before tightening mounting bolts. Do not under
any circumstances try to close gap by tightening mounting
bolts or the servo mount will be damaged.
•
NOTE
•
To facilitate gear alignment, use the correct orientation.
(c)
Install bolts and washers securing servo actuator to servo mount.
(d)
Torque bolts 35.0±5.0 in-lb (3.95±0.56 Nm).
(e)
Connect servo actuator connector to aircraft harness.
•
NOTE
•
Ensure that harness is properly secured to the airframe.
(f)
Reset YAW SERVO circuit breaker.
(g)
If GSA 80 has been replaced with a new or different unit, or original unit has been
repaired, perform Adjustment/Test - Component Software and Configuration
Loading.
(h)
Perform Operational Test - GFC 700 Autopilot.
(i)
23 Dec 2016