2.5.3
Bypass Capacitors
Each device power supply pin includes 0.1 µF bypass capacitors placed as close as possible to the pin.
Each power supply net includes at least 68 µF bulk capacitance as a charge well for transient current
loads.
Figure 4. Bypass Capacitor Placement
VD
Bypass
CS3302A
Device
VA+ bypass
VA- bypass