C
IRRUS
D
ESIGN
S
ECTION
3: E
MERGENCY
P
ROCEDURES
SR20
E
NVIRONMENTAL
S
YSTEM
E
MERGENCIES
P/N 11934-005
3-29
Environmental System Emergencies
CO LVL HIGH Warning
CO LVL HIGH
Carbon Monoxide Level High
1. Air Conditioner (if installed) ............................NOT IN RECIRC MODE
2. Temperature Selector .......................................................................... COLD
3. Vent Selector.................................. FEET/PANEL/DEFROST POSITION
4. Airflow Selector......................................SET AIRFLOW TO MAXIMUM
5. Panel Eyeball Outlets........................................................................... OPEN
◆
If CO LVL HIGH does not extinguish:
a. Supplemental Oxygen (if available)
(1)Oxygen Masks or Cannulas ...................................................... DON
(2)Oxygen System .............................................................................. ON
(3)Oxygen Flow Rate ..........................................................MAXIMUM
b. Land as soon as possible.
Procedure Complete
• N
OTE
•
Annunciation indicates carbon monoxide level is greater than 50
PPM. Ensure that air condition is not in recirculate mode and that
air temperature is set to full COLD to supply maximum amount of
fresh air to cabin.
Reissue A
Содержание 2220
Страница 12: ...SECTION 1 GENERAL CIRRUS DESIGN SR20 1 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 120: ...SECTION 4 NORMAL PROCEDURES CIRRUS DESIGN SR20 4 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 188: ...SECTION 6 WEIGHT AND BALANCE CIRRUS DESIGN SR20 6 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 198: ...SECTION 7 AIRPLANE AND SYSTEMS CIRRUS DESIGN SR20 7 4 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 326: ...SECTION 10 SAFETY INFORMATION CIRRUS DESIGN SR20 10 2 P N 11934 005 Reissue A Intentionally Left Blank ...