C
IRRUS
D
ESIGN
S
ECTION
7: A
IRPLANE
AND
S
YSTEMS
SR20
P
ITOT
-S
TATIC
S
YSTEM
P/N 11934-005
7-67
Pitot Heat Annunciation
Illumination of the PITOT HEAT FAIL Caution indicates that the Pitot
Heat switch is ON and the Pitot heater is not receiving electrical current.
Illumination of PITOT HEAT REQD Caution indicates the system detects
OAT is less than 41 °F (5 °C) and Pitot Heat Switch is OFF. A current sensor
on the Pitot heater power supply wire provides current sensing.
Alternate Static Source
An alternate static pressure source valve is installed on the switch and
control panel to the right of the pilot's leg. This valve supplies static pres-
sure from inside the cabin instead of the external static port. If erroneous
instrument readings are suspected due to water or ice in the pressure line
going to the standard external static pressure source, the alternate static
source valve should be turned on. Pressures within the cabin will vary with
open heater/vents. Whenever the alternate static pressure source is
selected, refer to
for airspeed calibration and
altitude corrections to be applied.
Reissue A
Содержание 2220
Страница 12: ...SECTION 1 GENERAL CIRRUS DESIGN SR20 1 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 120: ...SECTION 4 NORMAL PROCEDURES CIRRUS DESIGN SR20 4 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 188: ...SECTION 6 WEIGHT AND BALANCE CIRRUS DESIGN SR20 6 2 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 198: ...SECTION 7 AIRPLANE AND SYSTEMS CIRRUS DESIGN SR20 7 4 P N 11934 005 Reissue A Intentionally Left Blank ...
Страница 326: ...SECTION 10 SAFETY INFORMATION CIRRUS DESIGN SR20 10 2 P N 11934 005 Reissue A Intentionally Left Blank ...