E L E C T R I CA L W I R I N G C O N S I D E R AT I O N S
1 — E L E C T R I CA L P R OT E C T I O N S
Charge point may not include elements of electrical protection.
If this equipment has internal electrical protections, are installed in each socket-outlet
for the protection of the user against an electrical failure, according to the international
standard IEC 61851-1:2017.
In order to guarantee the total protection of the users and the installation (power
supply line included) in front of any electrical hazard, it is mandatory to install a main
circuit breaker (MCB) and a residual current device (RCD) upstream of the charger.
These electrical protections and the rest of the installation have to be aligned with the
local and national rules. The selectivity of the protections has to be guaranteed at all
times.
2 — P OW E R S U P P LY L I N E D I M E N S I O N I N G
The dimensioning of the input power supply line of the charge point must be checked
by a qualified electrician. Note that various factors such as cable length between
distribution board and charge point, maximum output current of the charge point may
have influence of the selected cable.
In such cases, increasing the cable cross-section it is required to adapt the temperature
resistance of the power supply line.
3 — M A X I M U M C U R R E N T O U T P U T
Please refer to the
TECHNICAL DATA
section to consult the default factory settings
from maximum output current of the charge point.
If the power supply is less than maximum output current and adjustment to a lower
nominal current needs to be performed, please refer to the
INSTRUCTION MANUAL
(M177B01-03-xxx).
Depending of the model this value may vary
.
Take into consideration this section before start wiring
connections of the charge point.
Before the
installation
07
Installation Guide
URBAN
Содержание URBAN M21
Страница 1: ...URBAN Series INSTALLATION GUIDE M177A01 03 19A...
Страница 4: ...1 04 URBAN Installation Guide...
Страница 12: ...3 446 438 288 234 1544 1351 113 80 180 Measures in mm 12 URBAN Installation Guide...
Страница 14: ...4 A 1 2 Opening Use provided key in order to open the unit Key type saw EMKA EK333 14 URBAN Installation Guide...
Страница 16: ...Firmly tighten the 4 nuts using a 24mm open end wrench C Fixation 16 URBAN Installation Guide...