5
ELECTRICAL DATA
URBAN MASTER - URBAN SLAVE
M2
T2
M2-C1
T2-C2
Power supply
1P+N+PE
3P+N+PE
1P+N+PE
3P+N+PE
Input voltage
230V~±10%
400V~±10%
230V~±10%
400V~±10%
Input current
32 A
Frequency
50Hz / 60Hz
Number of sockets
2
Maximum socket Power
7.4 kW
22 kW
7.4 kW
22 kW
Maximum Socket current
32 A
Connectors type
Type 2 Socket
Type 1 Cable
Type 2 Cable
Charging Mode
Mode 3
Min. cable cross-section
(3)
25 mm
2
Meter
MID Class 1 - EN50470-3
Overcurrent protection
MCB 40A (Curve C)
Safety protection
RCD Type A (30 mA) / Type B
(4)
Surge protection
(4)
Transient surge protector IEC 61643-1 (Class II)
URBAN M21, URBAN T21, URBAN M22, URBAN T22, URBAN T22-C, URBAN T24-MIX
M21
T21
M22
T22
T22-C
T24-MIX
Power supply
1P+N+PE
3P+N+PE
1P+N+PE
3P+N+PE
Input voltage
230V~± 10%
400V~± 10%
230V~±10%
400V~±10%
Input Current
35 A
67 A
Frequency
50Hz / 60Hz
Number of
sockets
1
2 : Socket A, Socket B
4
(5)
: 2 socket A,
2 socket B
Maximum
socket Power
7.4 kW
22 kW
7.4 kW
(socket A & B
)
22 kW
(socket A & B)
22 kW / 3.7 kW
(socket A & B)
Maximum
socket
current
32 A
32 A (socket A & B)
32 A / 16 A
(socket A & B)
Connectors
type
Type 2
Type 2 (socket A & B)
Type 2 / CEE 7/3
(socket A & B)
20
URBAN
Installation Guide
Содержание URBAN M21
Страница 1: ...URBAN Series INSTALLATION GUIDE M177A01 03 19A...
Страница 4: ...1 04 URBAN Installation Guide...
Страница 12: ...3 446 438 288 234 1544 1351 113 80 180 Measures in mm 12 URBAN Installation Guide...
Страница 14: ...4 A 1 2 Opening Use provided key in order to open the unit Key type saw EMKA EK333 14 URBAN Installation Guide...
Страница 16: ...Firmly tighten the 4 nuts using a 24mm open end wrench C Fixation 16 URBAN Installation Guide...