---------      EARTH RESISTANCE TESTER   

T-3V

      -------   Page  No.    1 

 - 

 

 

 

 T-3V ANALYZER CONTENTS     

                                                           

page No. 

 

1.-

 

GENERAL REMARKS.................................................................................................................. 2

 

1.1.- Description...................................................................................................................... 2

 

1.2.- Specifications  ................................................................................................................ 3

 

2.-

 

SAFETY ADVICE   ....................................................................................................................... 4

 

3.-

 

INSTRUCTIONS FOR USE.......................................................................................................... 5

 

3.1.- Description of the controls and the parts........................................................................ 5

 

3.2.- Use.................................................................................................................................. 6

 

4.-

 

MAINTENANCE............................................................................................................................ 7

 

4.1.- Replacing the batteries ................................................................................................... 7

 

4.2.- Cleaning and storage...................................................................................................... 7

 

4.3.- 5 TECHNICAL SERVICE................................................................................................ 7

 

 

 
 
 

SAFETY ADVICE 

Before handling the equipment read the instruction manual and in particular the 
SAFETY ADVICE section. 

The symbol  

  on the equipment means "PLEASE CHECK THE INSTRUCTION 

MANUAL". It may also appear as a warning or caution symbol in this manual. 
WARNING and CAUTION boxes may appear throughout this manual to avoid risk of 
accidents to persons or damage to the equipment or other property. 

 
 

Содержание T-3V

Страница 1: ...EARTH RESISTANCE TESTER T 3V Code M80410 INSTRUCTION MANUAL M98111001 03 04A CIRCUTOR S A...

Страница 2: ...he batteries 7 4 2 Cleaning and storage 7 4 3 5 TECHNICAL SERVICE 7 SAFETY ADVICE Before handling the equipment read the instruction manual and in particular the SAFETY ADVICE section The symbol on th...

Страница 3: ...to measure earth voltage The 2 mA measurement current allows floor resistivity to be tested without tripping the earth circuit breakers in the circuit to be checked Battery operation Self disconnectin...

Страница 4: ...EN61010 Battery low indicator The symbol B appears on the display Reading memory indicator The symbol DH appears on the display Over range indicator 1 in the most significant digit MSD Open circuit in...

Страница 5: ...operating conditions 1 INDOOR USE 2 Category III Installation 3 Degree of Pollution 2 4 Altitude up to 2 000 m 5 Max relative humidity 80 6 Ambient temperature 0 40 C WARNING Handle the rods without...

Страница 6: ...e controls and the parts 1 Female connector for earth connection 2 Operating open circuit indicator 3 Reading memory switch 4 Timer deactivation button 5 LCD Display 6 Female connectors for line condu...

Страница 7: ...han 10 V AC If not the accuracy of the earth resistance measurement cannot be guaranteed If the PUSH ON 9 button is pressed and the operating indicator 2 does not come on thisl means that there is an...

Страница 8: ...crew 4 2 Cleaning and storage Warning Avoid water getting into the case to prevent electrical discharge or damage to the tester Periodically clean the case with a soft cloth dampened with water and de...