![Circutor Raption 100 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/circutor/raption-100/raption-100_installation-manual_2608159052.webp)
MODELS SPECIFICATIONS
Raption 50 HV / Raption 50 EVO - 480V Models
Raption 50 HV
Power output DC of 50 kW (non upgradable).
Raption 50 EVO
Power output DC of 50 kW (upgradable up to 100 kW).
MODELS
CCS1
CCS1 CHA
CCS1 T1C32
Maximum AC input
current
63 A
63 A
63 A (@480V 3F)
35 A (@208-240V F-N)
Required power supply
capacity
53 kVA
53 kVA
75 kVA
Maximum output
power
DC:
50 kW (@400Vdc)
DC:
50 kW (@400Vdc)
DC:
50 kW(@400Vdc)
AC:
7.4 kW
Output voltage range
DC:
50 - 500 Vdc
DC:
50 - 500 Vdc
DC:
150 - 920 Vdc
AC:
208 - 240 V
~
Maximum output
current
DC:
125 A
DC:
125 A
DC:
125 A
AC:
32 A
Number of connectors
1
2
2
Connector type
M
B
MODELOS
CCS1 T2S32
CCS1-CHA T1C32
CCS1-CHA T2S32
Maximum AC input
current
63 A (@480V 3F)
35 A (@208-240V F-N)
63 A (@480V 3F)
35 A (@208-240V F-N)
63 A (@480V 3F)
35 A (@208-240V F-N)
Required power supply
capacity
75 kVA
75 kVA
75 kVA
Maximum output
power
DC:
50 kW(@400Vdc)
AC:
7.4 kW
DC:
50 kW(@400Vdc)
AC:
7.4 kW
DC:
50 kW(@400Vdc)
AC:
7.4 kW
Output voltage range
DC:
150 - 920 Vdc
AC:
208 - 240 V
~
DC:
150 - 920 Vdc
AC:
208 - 240 V
~
DC:
150 - 920 Vdc
AC:
208 - 240 V
~
Maximum output
current
DC:
125 A
AC:
32 A
DC:
125 A
AC:
32 A
DC:
125 A
AC:
32 A
Number of connectors
2
3
3
Connector type
C
M
M
B
C
52
Raption
Installation Guide
Содержание Raption 100
Страница 1: ...Raption Series INSTALLATION GUIDE M186A01 03 21D...
Страница 2: ...2 Raption Installation Guide...
Страница 15: ...15 Installation Guide Raption...
Страница 16: ...3 A Dimensions Units specified in millimeters 16 Raption Installation Guide...
Страница 56: ...56 Raption Installation Guide...
Страница 58: ...58 Raption Installation Guide...
Страница 59: ...59 Installation Guide Raption...