background image

 

 

 

 

 

Содержание RJ Series

Страница 1: ......

Страница 2: ...nerator CircuPool s high performance systems offer escape from the routine of manual pool chlorination and sanitization Please take a moment to read through the entire manual before installing your ne...

Страница 3: ...um life of the electrolytic cell is 15000 hours under normal use conditions DO NOT add acid directly to the skimmer This may damage the cell Check the expiration date of any test kits as test results...

Страница 4: ...tions Measure and cut out a section of pipe 6 7 8 at the desired location in the return pipe and install two 90 elbows glued to either side with the openings facing up Next glue a minimum 6 pipe with...

Страница 5: ...nt salt has been added and fully dissolved and circulated throughout pool water The RJ Series chlorine generator by electrolysis creates chlorine to sanitize your pool from the salt molecules NaCL in...

Страница 6: ...the ideal level for operation is about 3500 ppm To achieve this level of salinity add approximately 30 lbs of salt for every 1000 gallons of water or 3 6 Kilograms of salt for every 1000 Litres If yo...

Страница 7: ...mperatures it is advisable to activate the WINTER MODE Simply press once and the Winter Mode will accordingly reduce the chlorine output of the shown percentage by approximately half Reducing chlorine...

Страница 8: ...ork downward It will take a few days of adjustments to find the ideal setting for your pool Once determined it should only take minor adjustments Swimming Pools Spas Free Available Chlorine 1 0 3 0 pp...

Страница 9: ...move the cell plug connecting the cell to the Control Module 3 Unscrew threaded rings around the PVC piping connecting the cell to the return line plumbing 4 Pull entire cell away from the barrel unio...

Страница 10: ...water sample to a Pool Professional once per month Not Recommended List Do not allow fertilizer anywhere near your pool Fertilizers are one of many sources that contain Nitrates or Phosphates which ca...

Страница 11: ...e possible cause may be one or more of the following Insufficient chlorine output Insufficient running times Phosphates or Nitrates in the water Insufficient or excessive stabilizer pH too high Salt c...

Страница 12: ...d of eighteen months The warranty may be void if the following occurs 1 Damage beyond the control of CompuPool Products USA 2 Damage due to improper pool chemistry 3 Damage due to improper installatio...