SETUP
Page 25 of 36
3.3. LOGIX INTEGRATION
The CS-BRT20 Belt Rip and Tear Detector can be easily integrated with Allen-Bradley
Logix family of controllers.
3.3.1.
A
DD
M
ODULE TO
I/O
C
ONFIGURATION
The Belt Rip and Tear Detector must be added to the RSLogix 5000 / Studio 5000 I/O
tree as a generic Ethernet module. This is achieved by right clicking on the Ethernet
Bridge in the RSLogix 5000 and selecting New Module after which the ETHERNET-
MODULE is selected to be added as shown in the figure below.
NOTE
: See the next section for importing the configuration (L5X).
Figure 3.10 - Add a Generic Ethernet Module in RSLogix 5000
The user must enter the IP address of the Belt Rip and Tear Detector module that has
been configured. The assembly instance and size must also be added for the input,
output, and configuration in the connection parameters section.
The required connection parameters for the Belt Rip and Tea Detector module are
shown below:
Connection Parameter
Assembly Instance
Size
Input
163
100 (8-bit)
Output
164
20 (8-bit)
Configuration
102
0 (8-bit)
Table 3.1 - RSLogix class 1 connection parameters