OG_MU-D1-R_v10e Circuit Design, Inc.
33
OPERATION GUIDE
*The code is minus. Example: 6A=-106 dBm
*The response is returned in the order like Antenna A of Ch 1, Antenna B of Ch 1, Antenna A of Ch 2, Antenna
B of Ch 2…….
5.4.4 Test commands and Responses
5.4.4.1 @CT Test data transmission
Transmits test data from the source station for the time specified. Specify ‘ON’ to transmit data continuously, specify
a count value when transmitting for a specified time, and specify ‘OF’ to stop transmission. The transmission data is
‘
C
R
L
F
’ sent repeatedly, and the receive response of the target station is ‘*DR = 00’. If there is any input data during
transmission, the data is transmitted.
Default: ‘OF’
Value: ‘ON’: Continuous transmission (on), ‘OF’: Continuous transmission (off), Count value: ASCII code that
expresses 01h to FFh
The count value is 10 seconds per count. The maximum value is FFh, 2,550 seconds.
Example 1: Continuous data transmission on
Test command:
@CT
ON
C
R
L
F
Test response: *
CT = ON
C
R
L
F
Example 2: Continuous data transmission off
Test command:
@CT
OF
C
R
L
F
Test response:
*CT = OF
C
R
L
F
Example 3: Transmit data for 60 seconds
Test command:
@CT
06
C
R
L
F
Test response:
*CT = ON
C
R
L
F
④
Data receive *DR=00
・Source station 5F status
①
Issue the test command @CT 06 C
R
L
F
②
:
Test response *CT=ON C
R
L
F
・Status of all target stations
②
④
User
controller
User
controller
Target
station
Source
station
③
Transmit test data
①
③
Transmit test data
・If the Destination ID matches, data
receive is output for specified time.
・To measure the RSSI of the test signal,
set the target station Equipment ID to
‘FFh’ and use the ‘@RA’command.
5.4.4.2 @CP Packet test
Transmits data for packet testing.
Transmits data packets to the specified target unit, and the target unit returns the data without change. Any packet
length from 1 to 255 bytes can be specified.
Format : ‘@’ + ‘CP’ + data size + data + ‘C
R
L
F
’
Details
Format: ‘@CP’ ss DD....D ‘
C
R
L
F
’
ss: Shows the data size in 2 hexadecimal digits and ASCII characters. Value: 00h to FFh, maximum 255 bytes
DD...D: D expresses 1-byte data. Value: 00h to FFh, amount of data: maximum 255 bytes
Transmission is based on the content of the Destination ID. The equipment set as the Destination ID will be the
target station.
Example: Transmit ‘ABC’ from the source station with Equipment ID = 5F to target station Equipment ID = 8F, and
the data is returned without change.