OG_MU-D1-R_v10e Circuit Design, Inc.
32
OPERATION GUIDE
EFFA
(C6F7),
EFFB
(7F6F),
EFFC
(15C4),
EFFD
(0A34),
EFFE
(F7E8),
EFFF
(A09C)
Default: 0000h
Value: 0000h to FFFEh (0000h is for testing, FFFFh cannot be used)
Example: Set the User ID to 0000h with the password 0B27h provided.
Control command: @
UI
0000,0B27
C
R
L
F
Control response: *
UI = 0000
C
R
L
F
*
For ordinary applications, fix the UI, GI, and EI in the EEPROM with the command /W option.
* Please contact the distributor or Circuit Design, Inc. if you require multiple User IDs.
5.4.2.18 @VR Display program version
Obtains the program version of the MU-D1-R.
Example:
Control command:
@VR
C
R
L
F
Control response:
*
VR = 20 Ver2.0F-HP 2010/05/26 14:22
C
R
L
F
5.4.3 Monitor commands and Responses
5.4.3.1 @RA RSSI absolute value measurement
Measures the absolute value for Received Signal Strength Intensity (RSSI) of the antenna A and B at the channel
set. The measured value is a hexadecimal value that indicates the RSSI absolute value.
The code of the RSSI value acquired is minus.
Format 1: ‘@’ + ‘RA’ + ‘C
R
L
F
’
Details
Format:
‘@RA
C
R
L
F
’
Range of the hexadecimal value that indicates the RSSI absolute value: 00h to FFh
Example: Measure the RSSI absolute value of the current channel
Monitor command: @RA
C
R
L
F
Monitor response:
When RM = CD
*
RA 63 65
C
R
L
F
*63h=99:RSSI absolute value of the antenna A, 65h=101:RSSI absolute value of the antenna B
(When RM = TX *
RA = 63 -99dBm , 65
-101dBm C
R
L
F
)
5.4.3.2 @RC All channel RSSI absolute level measurement
Measures the RSSI (Received Signal Strength Intensity) over all channels. It is possible to check the floor noise
level of the field, third party field level, and field level of the system itself. The measured values of the antenna A and
B are alternately output as a 2-digit hexadecimal number in ASCII characters that express the absolute value for
RSSI. The code of the RSSI value acquired is minus.
Format 1: ‘@’ + ‘RC’ + ‘C
R
L
F
’
Details
Format:
‘@RC
C
R
L
F
’
Range of the hexadecimal value that indicates the RSSI absolute value: 00h to FFh
Example: Measure the RSSI absolute value over all channels
Monitor command: @RA
C
R
L
F
Monitor response: *RC = 7A7C7D……….7E7D
C
R
L
F
*A response is returned for 20 ch x 2 antennas of RSSI data (80- byte ASCII characters)