background image

 

6

 

H.1 – GENERAL COMMENTS

 

 

Part number identifiers (POSITION NUMBERS / POS. NO.’s) within parenthesis such as (8) refer to circled numbers 
shown on assembly drawings, Figures 4, 5 and 6. 

 

NOTE: 

If upon disassembly, significant wear on power or idler rotors or rotor housing is found, Imo Pump 
recommends replacement of entire pump

 

H.2 – TOOLS REQUIRED 

 

Procedures described in this manual require common mechanics hand tools, arbor press, torque wrench and 
suitable lifting device such as sling for smaller pumps or strap for larger models. 
 

H.3 – PUMP DISASSEMBLY 

 

Perform the following steps before disassembling pump: 

a)  If pump is driven by an electric motor, de-energize and lock out power to driver and tag power control 
 box 

WARNING - Out of Service

”.  Proceed similarly for other type drivers. 

b)  Close all inlet and outlet valves and tag valves “

WARNING - Out of Service

”. 

c)  Vent pressure in pump and drain pumped liquid. 
d)  Remove pipe fittings/flanges at pump inlet and outlet openings. 
e)  Remove bolts holding pump to its mounting. 
f)  Remove coupling hub and key (13) from power rotor (7) shaft and place pump on suitable workbench. 

 

NOTE:

  CFHN Series pumps incorporate highly finished precision parts that must be handled carefully to avoid 

damaging critical machined surfaces. Removed parts should be tagged for identification and their exact 
positions in pump should be noted so new and removed parts can be properly replaced. 

 

 

CAUTION

 

 

When removing inboard cover (4) from pump, DO NOT pull out power rotor (7) and idler rotors (8) at same time 
since they may drop out and be damaged. If rotors start to come out, hold them in place. 

 

1.  Remove inboard cover (4) from pump housing (1) after first removing bolts (3 or 6) from cover (4). 

 

2.  Remove O-ring (31) and stationary seat (see Figures 2 and 3) of seal (16) from inboard cover (4). 
 

 

CAUTION

 

 

In next step, rotors will be removed from pump. They will come out as a unit.  Use care to support rotor set as it is 
withdrawn from housing so idlers will not be dropped on floor.  

 

3.  Remove rotor set, power rotor (7) and two idler rotors (8), from pump by grasping and gently pulling on drive shaft 

end of power rotor (7).  When ends of idler rotors (8) clear discharge end of housing (1), hold all 3 rotors together 
and ease out as an assembly.  Once rotor assembly is removed, disengage both idler rotors (8) and set aside. 

 

4.  Mechanical Seal Removal - See Figures 2 and 3 below. 

 

a.  For Elastomer Bellows Type – Figure 2 – Slide rotating assembly off power rotor (7). 

 

b.  For Metal Bellows Type Seals – Figure 3 – Loosen set screw(s) at least 2 turns and slide rotating assembly

 

from power rotor  

 

NOTE: 

 

If only replacing seal, skip to Steps 3 through 10 in PUMP ASSEMBLY / REASSEMBLY section below to 
install new seal and complete pump reassembly. 

 

  If  remainder of pump needs to be disassembled, proceed with Step 5 immediately below.

 

 

 

WARNING

 

 

Fluid leakage may make floor slippery and cause personal injury when pump is removed from system or when it 
is disassembled. 

Содержание IMO CFHN Series

Страница 1: ...s manual AND the following CE compliant manuals should be read thoroughly and in their entirety prior to pump installation operation and maintenance Manual No SRM00100 Safety and Operation Manual Manu...

Страница 2: ...tact with electrical equipment can cause shock Contact of electrical equipment with water can cause shock Do NOT touch with wet hands Always disconnect when not in use CONTENTS Cover Sheet 1 Safety an...

Страница 3: ...overs only CFHN series pumps These pumps have been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on...

Страница 4: ...inlet pressure discharge pressure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from that of operational...

Страница 5: ...nt versions POS NO 6 Qty 6 on right angle inlet versions size 20 pumps POS NO 6 Qty 8 on right angle inlet versions of sizes 40 through 90 G INSPECTION Interval for inspection and replacement of worn...

Страница 6: ...removed parts can be properly replaced CAUTION When removing inboard cover 4 from pump DO NOT pull out power rotor 7 and idler rotors 8 at same time since they may drop out and be damaged If rotors s...

Страница 7: ...eve by pushing on ball bearing 11 inner ring only until ball bearing 11 is positioned against shoulder on power rotor 7 2 Install retaining ring 15 in groove into power rotor 7 3 Before installing sea...

Страница 8: ...SHOOTING Install coupling to pump drive shaft Align pump and driver shafts per Manual SRM00101 Connect piping to pump Open inlet and outlet line valves Vent air from seal chamber before starting pump...

Страница 9: ...9 Figure 4 CFHN020 Pumps...

Страница 10: ...10 Figure 5 CFHN040 060 and 090 Pumps 10...

Страница 11: ...VENT ORIENTATION NOT CRITICAL WITH VERTICAL MOUNTING 2 THESE PARTS FOR FOOT MOUNT OPTION ONLY INLET OUTLET SECTION A A 1 16 MAX 47 8 WEEP SEAL VENT 3 95 95 TORQUE TO 61 N M 7 N M 3 3 47 16 4 7 13 15 1...

Страница 12: ...12 CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2021 CIRCOR Pumps North America LLC All rights reserved...

Отзывы: