Remote control function
I
Remote control function is a potential free contact which allows the remote start and stop of a
charge transaction.
This remote control function is disabled by default, by means of a jumper (as shown in the picture
below). The jumper shall be removed to enable this function.
This Jumper (J7) can be found below the port BOR4 on the main PCB inside the Charge Point
When the jumper is removed, a device outside of the Charge Point can be placed to control
the charge transaction. This device should close the contact "START" to allow the charge
transaction. If the contact is open, the charge transaction wont be able to start.
BOR4
BOR4
JUMPER (J7)
NO JUMPER (J7)
DISABLED
ENABLED
(1)
(2)
(1) - Location of the BOR4 in the eNext Charge Point.
(2) - Location of the BOR4 in the eNext Elite Charge Point.
Do not remove the jumper if remote control function is not required, otherwise
the charge transaction process cannot start while the contact is open.
Содержание Wallbox eNext Series
Страница 1: ...Installation Manual Wallbox eNext Series ...
Страница 2: ...Wallbox eNext Series Installation Manual ...
Страница 4: ...Wallbox eNext Series Installation Manual ...
Страница 6: ...02 Wallbox eNext Series Installation Manual 1 ...
Страница 11: ...07 ...
Страница 14: ...10 Wallbox eNext Series Installation Manual 4 Dimensions in mm 39 335 315 200 335 ...
Страница 15: ...11 Dimensions 168 52 5 105 230 52 5 62 5 34 34 62 5 39 5 255 20 5 ...
Страница 19: ...15 C Positioning Drill the wall Drill bit M 6 8 Dimensions in mm 1100 255 230 115 ...
Страница 32: ...28 Wallbox eNext Series Installation Manual 7 ...
Страница 34: ...30 Wallbox eNext Series Installation Manual 8 ...
Страница 35: ...31 Notes ...