E7 – Owner’s Manual
Page
38
Item
Error Message
Descriptions
5.
MV VOLT OVERLOAD
CAUSE:
The generator output voltage is overloaded.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
6.
CMP CURR OVERLOAD
CAUSE:
The output current of the generator is over
3amps for 3 seconds.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
7.
CMP CURR OVERCURR
CAUSE:
The output current of generator is over
3.5amps for 1 second.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
8.
SHORT CIRCUIT
CAUSE:
The IGBT of generator is short circuit.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error
message pops up again, replace the generator.
9.
CURRENT STATE NG
CAUSE:
The output circuit of the generator is
abnormal or the coil did not connect to the
controller.
SOLUTION:
- Check the coil connection.
- If coil connection is correct, replace the generator.