9
NOTE: PRM for S2 and S4 or S1 and S3 are always the same.
The default for S1 and S3 is2400RPM, the adjustable range is 2400 to 2850RPM.
The default for S2 and S4 is 1500RPM.The adjustable range is 1000 to 2400PRM.
3.4 Pump Run Under Pre -programmed Conditions
Pump has three quick start button ECO/CLEAN/BOOST, as below figure. The default speed is
1500, 2400, 3250RPM respectively.
1) Be sure the pump is power on.
2) Press one of ECO/CLEAN/BOOST, the LED light on screen will be lit.
3) The screen will display STOP for 1 second, and run 2850PRM for 5 minutes. After 10
minutes, the pump will run on the selected speed.
4. Pump Run under MODE1/MODE2
4.1 MODE 1/MODE2 Introduction
MODE 1
MODE 2
16 hours running cycle
24 hours running cycle
Stage
Start
Time
Running Hour
Default
Speed
Quick
Start
Button
Stage
Start
Time
Running
Hour
Default
Speed
Quick
Start
Button
S1
6:00AM
3
(adjustable)
2400RPM
(adjustable)
CLEAN
S1
12:00
PM
6
(adjustable)
1500PM
(adjustable)
ECO
S2
9:00AM
5
(adjustable)
1500PM
(adjustable)
ECO
S2
6:00
AM
3
(adjustable)
2400RPM
(adjustable)
CLEAN
S3
6:00PM
3
(adjustable)
2400RPM
(adjustable)
CLEAN
S3
9:00
AM
9
(adjustable)
1500PM
(adjustable)
ECO
S4
9:00PM
5
(adjustable)
1500PM
(adjustable)
ECO
S4
6:00
PM
6
(adjustable)
2400RPM
(adjustable)
CLEAN
1000-2400RPM
DEFAULT: 1500
CLEAN
2400-2850RPM
DEFAULT: 2400
2850-3450RPM
DEFAULT: 3250
ECO
BOOST
Indicator Light