background image

 

Use FuzzyScan in SPP Mode 

Establish SPP Master Connection 

Look for the Bluetooth host device’s MAC address under its “Hardware” 

or “Bluetooth” settings. You will need this MAC address later on. 

 

Ensure that a virtual COM port is available on your host device for 

scanner connection. If not, perform the steps required on your host 

device to add one. For example, go to “Local Services” under “

Bluetooth 

Advanced Settings

” and click on “

Add Serial Services

” to add a virtual 

incoming COM port. 

 

Power on the scanner within radio coverage and make  sure  its  status 

indicator gives 

alternative red and green blinks

 (in “

Uninstall” 

state). If 

not, scan the “Uninstall” barcode to release its current pairing. 

 

 

Uninstall 

 

Scan the “

SPP Master Simple Mode

”  barcode . The scanner’s status 

indicator will turn steady red immediately. 

 

 

 

SPP Master Simple Mode 

 

Scan the 12 option codes (see Appendix) that correspond to your host 

device’s MAC address, then scan the “FIN”  barcode.  The scanner will 

emit a series of clicking sounds and its link  indicators will flash blue 

rapidly. 

 
Launch your terminal application  to  connect it  with the scanner. The 

scanner will emit 4 beeps in ascending tone to indicate radio connection, 

and its link indicator will 

flash blue every 2.5 seconds

   

If the scanner fails to pair with host device within 30 seconds, its link 

indicator will give 3 blue blinks every 2 seconds. Thereafter, the scanner 

will continue to search for your host device for another 30 seconds before 

going into “Radio-Off” state. In the interim, you may scan the “Uninstall” 

command to set your scanner to the “Uninstall” state. If the scanner has 

entered radio-off state already, you can wake the scanner by pressing its 

trigger; this will also cause the scanner to re-attempt pairing. 

 

The  above  procedures  are based on popular Windows  operation 

environment. But the installation procedure may vary depending on 

different remote host devices, operating systems and the Bluetooth 

drivers. Please consult your professional IT consultant to obtain 

necessary support if any problem is  arouse  during the installation 

processes. For more detailed information, please visit CINO website.   

Содержание A660BT Series

Страница 1: ...FUZZYSCAN FAMILY Quick Start Guide Bluetooth Version CORDLESS SCANNER...

Страница 2: ...ing performance but also delivers the convenience and freedom of mobility It s ideal for a broad range of applications to unleash your productivity with ease This document provides a quick reference f...

Страница 3: ...the status indicator will be steady green Please charge the new battery pack for 8 hours before its first use Ensure the battery contacts of the battery pack are facing the charging contacts inside t...

Страница 4: ...fers the legacy cabled interfaces to the host device including USB HID USB COM and RS232 Serial PICO Mode For the requirement of multiple connections up to 7 scanners can be connected to one smart cra...

Страница 5: ...cking sounds and its link indicator will flash blue rapidly Once pairing is completed the scanner will beep 4 times in ascending tone and its link indicator will flash blue every 2 5 seconds The smart...

Страница 6: ...indicators will then emit alternating red and green blinks Uninstall Scan the Quick Pair barcode for PICO mode which you have created in advance with your scanner This will launch the pairing process...

Страница 7: ...xecute the Bluetooth Discovery procedure to find nearby Bluetooth device then select F L A xxxBT xxxx the xxxx are the last 4 digits of its MAC address The scanner will emit 4 beeps in ascending tone...

Страница 8: ...ries of clicking sounds and its link indicators will flash blue rapidly Launch your terminal application to connect it with the scanner The scanner will emit 4 beeps in ascending tone to indicate radi...

Страница 9: ...anner is successfully discovered Perform the steps required on your host device to activate the pairing e g tapping or double clicking on the model number etc During the pairing process the scanner wi...

Страница 10: ...to indicate the radio connection rebuilt and the scanner s link indicators blink blue once per 2 5 seconds At the same time all the stored scanned data will be transmitted automatically right after t...

Страница 11: ...is full If the storage is full you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage To terminate the batch scanning please scan the Exit Batch Scanning...

Страница 12: ...Transmit Stored Data The scanner is preset to transmit all stored data by scanning the Transmit Stored Data command During the transmission the scanner will emit continuous short clicks and the link...

Страница 13: ...Simple Mode UNINSTALL Host Interface Quick Set for Smart Cradle only RS232 Serial USB HID Standard Mode USB HID Turbo Mode USB Com Port Emulation Keyboard Layout Quick Set USA Latin America United Ki...

Страница 14: ...aging Master Default PowerTool Host Link Switch On screen Keyboard Save Configuration Factory Default Power Off Clone Operation Mode Quick Set Trigger Mode Presentation Mode Option Codes 0 8 4 C 1 9 5...

Страница 15: ...ed blink 8 beeps Good read 1 green blink 1 good read beep Under Configuration Steady red Off Uninstall state Alternative red and green blinks Off Upgrade state Steady red Short click Time out warning...

Страница 16: ...om the date of shipment provided that the product is operated under normal and proper conditions The warranty provisions and durations are furnished by different warranty programs The above warranty d...

Отзывы: