Cineo Edge 160 Скачать руководство пользователя страница 9

9

Adjusting DMX starting Address

With LOCAL control enabled, when the display is showing the DMX Address, pressing the UP or DOWN 
buttons changes the starting address for DMX. You must press the ENTER button within 20 seconds in 
order to keep the new DMX address; otherwise it will revert to the previous address. The example to the 
right shows the display for Address 001.

Adjusting the DMX Personality

With LOCAL control enabled, when the display is showing DMX Personality, for example “HSIC08”, it 
reflects the DMX Personality currently set. It can be modified using the UP and DOWN buttons followed 
by ENTER. The 4 personality options are: HSIC16, HSIC08, RGBC16, RGBC08. 

In HSIC personality, the following four DMX slots are (in sequence): Intensity, CCT, Saturation and Hue, 
and can be operated in 8-bit or 16-bit DMX resolution. 

In RGBC personality, the following four DMX slots are (in sequence): Red, Green, Blue and CCT. Select 8-bit 
or 16-bit resolution.

You must press the ENTER button within 20 seconds in order to keep the new DMX address; otherwise it 
will revert to the previous address.

Note that 16-bit resolution personalities are selected, the LOCAL controls also operate at the higher 
resolution.

Adjusting DMX Slot 1

This shows the first DMX slot value based on the current personality setting. The control console can 
change the value of this channel using the UP/DOWN buttons, and results are reflected on the output of 
the fixture. . No “ENTER” is required for the new value to take effect.  

If the unit is in either 8-bit or 16-bit HSIC personalities, this slot adjusts Intensity, or overall output, 0-100%.

If the unit is in either RGBC personalities, this slot adjusts the value of the Red channel, 0-100%

Adjusting DMX Slot 2

This shows the second DMX slot value based on the current personality setting. The control console can 
change the value of this channel using the UP/DOWN buttons, and results are reflected on the output of 
the fixture. No “ENTER” is required for the new value to take effect.  

If the unit is in either 8-bit or 16-bit HSIC personalities, this slot adjusts CCT, in values from 2700 to 6500K.

If the unit is in either RGBC personalities, this slot adjusts the value of the Green channel, 0-100%.

Содержание Edge 160

Страница 1: ...Lightblade Edge User Guide Revision 1 0 January 2019 Information and specifications in this document are subject to change without notice w w w c i n e o l i g h t i n g c o m...

Страница 2: ...M in either 8 or 16 bit resolution Operating modes include both Hue Sat Intensity CCT and Cineo s Smart RGB mode with individual Red Green Blue CCT controls that automatically delivers optimum white l...

Страница 3: ...re Set Up Read these safety instructions carefully to ensure fixture and accessories are used safely Ensure the mounting hardware is correctly connected to the fixture before rigging Always use second...

Страница 4: ...D 24 W 12 5 H 4 7 D 48 W 12 5 H 4 7 D 610mm W 64mm H 64mm D 1 2m W 64mm H 64mm D 610mm W 178mm H 87mm D 1 2m W 178mm H 87mm D 610mm W 317 5mm H 120mm D 1 2m W 317 5mm H 120mm D Weight 1 4 lb 6 kg 2 7...

Страница 5: ...ge uses two separate LED engines to independently generate accurate white light variable from 2700K to 6500K and an extended RGB gamut for broad saturated color space The CIE 1931 diagram illustrates...

Страница 6: ...n to all attached Lightblades and a RJ45 to 5 pin XLR passive adapter for DMX For convenience the Power Chassis also includes carrying handles and additional mounting options 4 Additional mounting equ...

Страница 7: ...ain The RJ45 jacks conform to the industry standard for DMX over CAT5 6 cable It is not compatible for network connections Pin 1 Data Pin 2 Data Pin 7 Common Pin 8 Common The 5 pin XLR wiring is as fo...

Страница 8: ...ed If no DMX is present the unit displays LOCAL and local control is enabled Local Control The control module includes four color coded buttons with functions as follows MENU Blue Button This selects...

Страница 9: ...r to keep the new DMX address otherwise it will revert to the previous address Note that 16 bit resolution personalities are selected the LOCAL controls also operate at the higher resolution Adjusting...

Страница 10: ...16 BIT Standard DMX data structure is 8 bit which limits the value range between 0 255 This is the preferable operating mode for maximum compatibility with DMX controllers If more precise control is r...

Страница 11: ...is technically considered RGBC where the reference white point can be selected as well as values of the primary Red Green and Blue channels This is extremely valuable in correlating RGB operation in...

Страница 12: ...o camera stops DMX Value Output increase Stop Increase 0 100 20 100 0 40 200 1 60 400 2 80 800 3 100 1600 4 Here are examples of how to accurately match camera stops to dimming levels in Local Mode Lo...

Страница 13: ...5 50 128 Cyan 127 4 Stops 050 6500 255 80 204 Blue 170 Off 000 100 255 Magenta 212 Note that changing the DMX values in sequential steps as in performing a live dim to zero will add a dimming hysteres...

Страница 14: ...st be provided ESD and LED s LED components used in the Lightblade Edge are ESD Electro Static Discharge sensitive To prevent the possibility of destroying LED components do not touch either while in...

Страница 15: ...ING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT OR ANY OTHER WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEAL...

Страница 16: ...ct to change without notice Cineo Lighting are registered trademarks of Cineo Lighting Inc 2019 Cineo Lighting Inc v1 0 01 23 19 Cineo Lighting P O Box 808 El Granada CA 94018 Silicon Valley Los Angel...

Отзывы: