Cineo Edge 160 Скачать руководство пользователя страница 6

6

System Components, Connections and Controls

Components

All Lightblade Edge configurations feature these characteristics:

The Lightblade Edge system essentially includes four different components that can be combined or 
used individually to create optimized lighting fixtures and systems. These are:

1.  Lightblade Lampheads

Linear LED soft light sources, supporting five LED channels: R, G, B, 2700K, 6500K. They are available in 
both 24” (61 cm) and 48” (122 cm) lengths. Lightblade lampheads connect exclusively to Lightblade 
Controllers via 10-wire RJ50 cables.

2.  Lightblade Controllers

Lightblade Controllers are designed to provide both power and control to their attached Lightblade 
lamphead. Each Lightblade Controller connects to a single Lightblade lamphead. Connections include 
AC power and DMX/RDM. Local control is also provided. A secure 3/8-16 threaded mounting hole is 
provided for attaching to standard grip equipment.

3.  Power Chassis

The Lightblade Power Chassis is a convenient way to mount, power and control banks of Lightblades. 
These come in two configurations: 2-Blade and 4-Blade. Power Chassis can accommodate both 2’ or 4’ 
Blades. The Power Chassis provides a power switch for the entire fixture, AC distribution to all attached 
Lightblades and a RJ45-to-5-pin XLR passive adapter for DMX. For convenience, the Power Chassis also 
includes carrying handles and additional mounting options.

4.  Additional mounting equipment

In addition to mounting a Lighblade fixture with the included 5/8” baby pin, a QuikClik mounting clip 
is available for mounting individual blades separate from the controller. The Power Chassis can be 
mounted with the included baby pin, or can be used with a twist-on Omnimount plate.

Power Connections

The individual Lightblade Edge units are powered by a 110 – 240VAC power supply, internal to the 
controller. Typical power connection is via the attached IEC pigtail. Alternatively, the controller can be 
hard-wired using the power bus connectors, which are accessed by removing the safety power cover. 

The Lightblade Edge fixtures can be configured into multi-blade fixtures using the Lightblade Power 
Chassis, which are available in 2-Blade and 4-Blade configurations. These power chassis provide mounting 
support, AC power distribution and switching, as well as convenient DMX connections in standard 5-pin 
XLR connectors.

NOTES: 

1. Ensure the power cable is disconnected before servicing. 

2. Do not connect to a variable supply, such as a dimmer rack. 

3. A self-resetting thermal breaker is located within the individual Lightblade controllers. The Power 
Chassis also includes a fuse in the switch/IEC connector module. 

Содержание Edge 160

Страница 1: ...Lightblade Edge User Guide Revision 1 0 January 2019 Information and specifications in this document are subject to change without notice w w w c i n e o l i g h t i n g c o m...

Страница 2: ...M in either 8 or 16 bit resolution Operating modes include both Hue Sat Intensity CCT and Cineo s Smart RGB mode with individual Red Green Blue CCT controls that automatically delivers optimum white l...

Страница 3: ...re Set Up Read these safety instructions carefully to ensure fixture and accessories are used safely Ensure the mounting hardware is correctly connected to the fixture before rigging Always use second...

Страница 4: ...D 24 W 12 5 H 4 7 D 48 W 12 5 H 4 7 D 610mm W 64mm H 64mm D 1 2m W 64mm H 64mm D 610mm W 178mm H 87mm D 1 2m W 178mm H 87mm D 610mm W 317 5mm H 120mm D 1 2m W 317 5mm H 120mm D Weight 1 4 lb 6 kg 2 7...

Страница 5: ...ge uses two separate LED engines to independently generate accurate white light variable from 2700K to 6500K and an extended RGB gamut for broad saturated color space The CIE 1931 diagram illustrates...

Страница 6: ...n to all attached Lightblades and a RJ45 to 5 pin XLR passive adapter for DMX For convenience the Power Chassis also includes carrying handles and additional mounting options 4 Additional mounting equ...

Страница 7: ...ain The RJ45 jacks conform to the industry standard for DMX over CAT5 6 cable It is not compatible for network connections Pin 1 Data Pin 2 Data Pin 7 Common Pin 8 Common The 5 pin XLR wiring is as fo...

Страница 8: ...ed If no DMX is present the unit displays LOCAL and local control is enabled Local Control The control module includes four color coded buttons with functions as follows MENU Blue Button This selects...

Страница 9: ...r to keep the new DMX address otherwise it will revert to the previous address Note that 16 bit resolution personalities are selected the LOCAL controls also operate at the higher resolution Adjusting...

Страница 10: ...16 BIT Standard DMX data structure is 8 bit which limits the value range between 0 255 This is the preferable operating mode for maximum compatibility with DMX controllers If more precise control is r...

Страница 11: ...is technically considered RGBC where the reference white point can be selected as well as values of the primary Red Green and Blue channels This is extremely valuable in correlating RGB operation in...

Страница 12: ...o camera stops DMX Value Output increase Stop Increase 0 100 20 100 0 40 200 1 60 400 2 80 800 3 100 1600 4 Here are examples of how to accurately match camera stops to dimming levels in Local Mode Lo...

Страница 13: ...5 50 128 Cyan 127 4 Stops 050 6500 255 80 204 Blue 170 Off 000 100 255 Magenta 212 Note that changing the DMX values in sequential steps as in performing a live dim to zero will add a dimming hysteres...

Страница 14: ...st be provided ESD and LED s LED components used in the Lightblade Edge are ESD Electro Static Discharge sensitive To prevent the possibility of destroying LED components do not touch either while in...

Страница 15: ...ING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT OR ANY OTHER WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEAL...

Страница 16: ...ct to change without notice Cineo Lighting are registered trademarks of Cineo Lighting Inc 2019 Cineo Lighting Inc v1 0 01 23 19 Cineo Lighting P O Box 808 El Granada CA 94018 Silicon Valley Los Angel...

Отзывы: