7

Data Connections

All connectors for the Lightblades and their connected controllers are located on the ends of the units.  
Note that the cable connecting the Lightblade and controller is RJ50 (10-wire). This differs from standard 
RJ45 connectors (8 wire); these cables are NOT cross-compatible. DMX/RDM connectors use (2) RJ45 
connectors, located on the opposite end of the controller. These are passive feed-through connectors 
and are not load-terminated.

Wired DMX Connections

 

Depending on the configuration, Lightblade Edge use either RJ45 connectors or 5-Pin XLR male and 
female connectors to receive and forward DMX and RDM signals. The RJ45 ports are loop-thru connectors 
with no built-in termination, while the 5-pin XLR connectors on the Power Chassis is self-terminating and 
does not require external DMX termination when used in a chain. 

The RJ45 jacks conform to the industry-standard for DMX over CAT5/6 cable. It is not compatible for 
network connections:

• Pin 1: Data +

• Pin 2: Data – 

• Pin 7: Common

• Pin 8: Common

The 5-pin XLR wiring is as follows:

• Pin 1: Signal Common 

• Pin 2: Data – 

• Pin 3: Data +

• Pin 4: Spare

• Pin 5: Spare

Controls

The Lightblade Edge automatically selects LOCAL or DMX control modes, based on presence of valid 
DMX signal. The control module, located on the back of each Lightblade Controller allows the user to 
monitor (in DMX mode) or modify (in LOCAL mode) the operating parameters of the fixture. It includes 
(4) push-buttons and a 6-character display. 

The Lightblade Controller displays and provides the controls to potentially change these six settings, 
which subsequently alters the way the attached Lightblade operates. The display uses a single character 
“Label” to show which parameter is being displayed and potentially adjusted, followed by the value. 
All button presses are “rotating thru” so if the button is continually pressed it rotates thru all options or 
values.

Содержание Edge 160

Страница 1: ...Lightblade Edge User Guide Revision 1 0 January 2019 Information and specifications in this document are subject to change without notice w w w c i n e o l i g h t i n g c o m...

Страница 2: ...M in either 8 or 16 bit resolution Operating modes include both Hue Sat Intensity CCT and Cineo s Smart RGB mode with individual Red Green Blue CCT controls that automatically delivers optimum white l...

Страница 3: ...re Set Up Read these safety instructions carefully to ensure fixture and accessories are used safely Ensure the mounting hardware is correctly connected to the fixture before rigging Always use second...

Страница 4: ...D 24 W 12 5 H 4 7 D 48 W 12 5 H 4 7 D 610mm W 64mm H 64mm D 1 2m W 64mm H 64mm D 610mm W 178mm H 87mm D 1 2m W 178mm H 87mm D 610mm W 317 5mm H 120mm D 1 2m W 317 5mm H 120mm D Weight 1 4 lb 6 kg 2 7...

Страница 5: ...ge uses two separate LED engines to independently generate accurate white light variable from 2700K to 6500K and an extended RGB gamut for broad saturated color space The CIE 1931 diagram illustrates...

Страница 6: ...n to all attached Lightblades and a RJ45 to 5 pin XLR passive adapter for DMX For convenience the Power Chassis also includes carrying handles and additional mounting options 4 Additional mounting equ...

Страница 7: ...ain The RJ45 jacks conform to the industry standard for DMX over CAT5 6 cable It is not compatible for network connections Pin 1 Data Pin 2 Data Pin 7 Common Pin 8 Common The 5 pin XLR wiring is as fo...

Страница 8: ...ed If no DMX is present the unit displays LOCAL and local control is enabled Local Control The control module includes four color coded buttons with functions as follows MENU Blue Button This selects...

Страница 9: ...r to keep the new DMX address otherwise it will revert to the previous address Note that 16 bit resolution personalities are selected the LOCAL controls also operate at the higher resolution Adjusting...

Страница 10: ...16 BIT Standard DMX data structure is 8 bit which limits the value range between 0 255 This is the preferable operating mode for maximum compatibility with DMX controllers If more precise control is r...

Страница 11: ...is technically considered RGBC where the reference white point can be selected as well as values of the primary Red Green and Blue channels This is extremely valuable in correlating RGB operation in...

Страница 12: ...o camera stops DMX Value Output increase Stop Increase 0 100 20 100 0 40 200 1 60 400 2 80 800 3 100 1600 4 Here are examples of how to accurately match camera stops to dimming levels in Local Mode Lo...

Страница 13: ...5 50 128 Cyan 127 4 Stops 050 6500 255 80 204 Blue 170 Off 000 100 255 Magenta 212 Note that changing the DMX values in sequential steps as in performing a live dim to zero will add a dimming hysteres...

Страница 14: ...st be provided ESD and LED s LED components used in the Lightblade Edge are ESD Electro Static Discharge sensitive To prevent the possibility of destroying LED components do not touch either while in...

Страница 15: ...ING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT OR ANY OTHER WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEAL...

Страница 16: ...ct to change without notice Cineo Lighting are registered trademarks of Cineo Lighting Inc 2019 Cineo Lighting Inc v1 0 01 23 19 Cineo Lighting P O Box 808 El Granada CA 94018 Silicon Valley Los Angel...

Отзывы: