background image

5. Wiring Connections: All wiring connections should be made for the proper voltage and phase as shown on the

motor nameplate. Connections should follow the motor manufacturers recommendations as shown on the wiring
schematic. This wiring diagram will be located on the outside of the motor, inside of the motor conduit box or on the
motor nameplate.

Reversing some wires might be necessary to get the correct blower rotation.

6. Motors with Thermal Overload Protection: If a motor is equipped with thermal overloads, the thermal overload

must be wired per the wiring schematic to be operable.

There are 3 types of thermal overloads:

a. Automatic: These will automatically shut the motor down if the internal temperature exceeds the design limits.

OMM-23-1009-page 6

MAKE SURE YOU LOCK OUT THE POWER TO THE MOTOR BEFORE INSPECTING ANY MOTOR WITH

AUTOMATIC THERMALS. WHEN THE THERMALS COOL DOWN, THEY WILL ALLOW THE MOTOR TO

AUTOMATICALLY START UP AGAIN, UNLESS YOU HAVE LOCKED OUT THE POWER TO THE MOTOR.

DANGER

b. Manual: These motors will have a button on them. If the motor overheats, it will shut down. After you have

inspected the motor and eliminated the over heating problem, you will need to “reset” it by pushing the button.
You should still lock out the power BEFORE inspecting the motor.

c. Thermostats: This type of thermal is a temperature sensing device ONLY. If the motor overheats, the thermo-

stats will open or close (depending on the type) and send a

“signal” to the electrical box. THEY WILL NOT

TURN THE MOTOR OFF. These are pilot circuit devices that must be connected to the magnetic starter
circuit.

7. EXPLOSION PROOF Motors: No motor is explosion proof. Explosion proof (EXP) motors are designed so if there is

an explosion

WITHIN the motor, the explosion will be CONTAINED INSIDE the motor and not allowed to get out to

the atmosphere. All explosion proof motors must be selected based on the atmosphere and/or the environment the
motor will be operating in. Explosion proof motors are designed, rated, and labeled for their operating conditions
based on Classes, Groups and “T” Codes.

The Class, Group and “T” Code of an EXP motor MUST be selected

based on the atmosphere and/or environmental conditions the motor will be operating in. Consult the NEC
(National Electric Code) and the NFPA (National Fire Protection Association) for the proper EXP motor
Class, Group and “T” Code required for your specific application and location.

NOTICE:

a. All EXP motors have some type of thermal overload as required by UL (Underwriters Laboratories).

Refer to all of Section 6 above.

b. All EXP motors are required to have the UL (Underwriters Laboratories) and CSA (Canadian Standards

Association) listing numbers on the motor name plate or on a separate plate attached to the motor. The
Class, Group and “T” Code the motor is designed for must also be listed.

8. Normal Motor Operating Temperatures:

Using your hand to test the normal running temperature of a motor can be a very painful experience;

The normal operating temperature of a fully loaded, open type, electric motor operating in a 70°F. (21° C.)
ambient temperature is 174°F. (79° C.)

C. Maximum Blower Speed and Motor Speed Controllers:

If you will be using any type of motor speed controller with this blower,

DO NOT exceed the maximum safe blower

speed. Installing and using a speed control device requires special training and certification as required by the
speed control manufacturer. See the manufacturers instructions for proper use, installation and wiring connections
for the maximum speed settings. It may also be necessary to “block out” some speeds to eliminate a resonant vibra-
tion problem. The maximum safe blower speed is shown on the data sheet shipped with the blower. If you have lost
the data sheet, contact Cincinnati Fan or our sales office for your area. You must have the serial number from the
blower name plate for us to determine the maximum safe blower speed. Cincinnati Fan will only extend the motor
manufacturers warranty, when used with a speed controlling device, if the motor has the words

“Inverter Duty”

marked on the motor name plate. If the motor does not have

“Inverter Duty” marked on the motor name plate, and

you have a motor failure, you will be required to contact the motor manufacturer for any service or warranty claims.

IF AN EXPLOSION PROOF MOTOR IS USED IN AN AREA CONTAINING VOLITILE LIQUIDS, GASES,

FUMES OR DUST FOR WHICH THE MOTOR WAS NOT DESIGNED TO OPERATE IN, AN

EXPLOSION AND/OR FIRE CAN OCCUR.

DANGER

Содержание LM

Страница 1: ... need to order any replacement parts special instructions may be required NOTICE LONG TERM STORAGE NOTICE If this blower will NOT be installed and put into operation within 30 days refer to the Long Term Storage Instructions on pages 12 and 13 Failure to follow all applicable long term storage instructions will void your warranty This blower should be stored indoors in a clean dry location BLOWER ...

Страница 2: ...r when removing it from the packaging container All the packaging material should be kept in the event the blower needs to be returned Handling Handling of the blower should be performed by trained personnel and be consistent with all safe handling practices Verify that all lifting equipment is in good operating condition and has the proper lifting capacity The blower should be lifted using well p...

Страница 3: ...dance with OSHA regulations Power to the blower should NOT be tuned back on until the required guards have been repaired or replaced This blower can become dangerous due to a potential windmill effect even though all electrical power has been turned off or disconnected The blower wheel should be carefully secured to prevent any rotational turning BEFORE working on any parts of the blower motor ass...

Страница 4: ...eters from the blower Any duct elbows located closer than 2 wheel diameters to the blower inlet or discharge WILL reduce the air performance and blower efficiency Any duct elbows near the blower discharge should be in the same rotational direction as the blower rotation Non Ducted Blower Inlet Any blower with no ducting on the inlet must have an inlet guard The blower should be located so the blow...

Страница 5: ...ay fuses or breakers should be used since the initial start up time for the blower motor although rare can be up to 10 seconds B Motors 1 DO NOT connect or operate a motor without reading the motor manufacturers instructions supplied with the blower The basic principle of motor maintenance is KEEP THE MOTOR CLEAN AND DRY This requires periodic inspections of the motor The frequency of the inspecti...

Страница 6: ... selected based on the atmosphere and or environmental conditions the motor will be operating in Consult the NEC National Electric Code and the NFPA National Fire Protection Association for the proper EXP motor Class Group and T Code required for your specific application and location NOTICE a All EXP motors have some type of thermal overload as required by UL Underwriters Laboratories Refer to al...

Страница 7: ... to a gradual rate of temperature increase not to exceed 15 F minute 8 C minute The same temperature limits are also important when the blower is experiencing a drop in temperature until the temperature drops down to 150 F 65 C Only when the entire blower has reached an equilibrium tempera ture of 150 F 65 C or less should the power be turned off 12 Make sure the power source connections to the bl...

Страница 8: ...end as per Fig 3 below After you have taken your vibration readings write them down in the spaces below and keep for future comparison OMM 23 1009 page 8 If the blower is going to be conveying material it is the users responsibility to periodically turn the blower off and lock out the power The blower wheel should then be checked for material build up and or erosion If material has built up on any...

Страница 9: ... CINCINNATI FAN OR OUR SALES OFFICE FOR YOUR TERRITORY TO DETERMINE IF THE UNIT WILL OPERATE SAFELY AT THE NEW CONDITIONS WARNING V ROUTINE INSPECTION MAINTENANCE Periodic inspection of all the blower parts is the key to good maintenance and trouble free operation The frequency of inspections must be determined by the user and is dependent upon the severity of the application BUT it should NEVER e...

Страница 10: ...through the motor and damage the motor bearings 2 Grinding off material for cast aluminum wheels If you are grinding on the wheel to remove material be very careful not to grind too much in one area That could affect the structural integrity of the wheel 3 Forward curved wheels Model LM only also known as squirrel cage or multivane wheels These wheels have balancing clips attached to individual bl...

Страница 11: ...Y PARTS CORRECTLY VII TROUBLESHOOTING Troubleshooting should only be performed by trained personnel Any potential electrical problems should only be checked by a licensed electrician All safety rules regulations and procedures MUST be followed Failure to follow proper procedures can cause property damage severe bodily injury and death DANGER PROBLEM CAUSE Excessive Vibration 1 Loose mounting bolts...

Страница 12: ...aintenance 2 The blower should be supported under each corner of its base to allow it to breath Supports 2 x 4 s timbers or railroad ties should be placed diagonally under each corner 3 If the equipment is to be stored for more than three 3 months the entire blower assembly must be loosely covered with plastic but not tightly wrapped 4 Storage Maintenance A periodic inspection and maintenance log ...

Страница 13: ... insulation resistance b DO NOT lubricate the motor bearings during storage Motor bearings are packed with grease at the factory c If the storage location is damp or humid the motor windings must be protected from moisture This can be done by applying power to the motor s space heaters IF AVAILABLE while the motor is in storage If the motor does not have space heaters storing it in a damp or humid...

Страница 14: ...to the replacement free of charge of parts returned at Purchaser s expense F O B Seller s plant and found to be defective by the Seller IN NO EVENT WILL SELLER BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER IN CONTACT TORT NEGLIGENCE STRICT LIABILITY OR OTHERWISE INCLUDING WITHOUT LIMITATION DAMAGES FOR INJURY TO PERSONS OR PROPERTY LOST PROFITS OR REVENUE LOST SALES OR...

Страница 15: ...1 For the parts drawing of all the standard components and specifications for the specific blower or fan that you have please contact our local Cincinnati Fan sales office for your area You will need to give them the serial number shown on the blower or fan nameplate so they can supply you the correct information Click on Contact a Sales Rep on our website for the name and contact information for ...

Отзывы: