8
LIGHTING BURNER(S)
WARNING! NEVER LIGHT BURNER WITHOUT ASPHALT COMPLETELY COVERING
FLUES. UNCOVERED FLUES GET TOO HOT AND CAN CAUSE A FIRE OR FLASH.
SERIOUS INJURY CAN RESULT.
MAIN TANK VALVE
BALL VALVE ON REGULATOR
Be sure the Ball Valve attached to the Regulator is CLOSED
Open the LP Tank Valve slowly to wide open.
Set the Pressure Regulator to 15 PSI.
Set Ball Valve on LP Tank to 1/3 open.
Ignite the Lighter Wand.
On the Safety Valve, press and hold Red Button for 1 second then let go.
Hold the tip of lit Ignitor Wand near the back of the Burner.
AT THE SAME TIME press and hold the Red Button on Safety Valve.
Once Burner lights, remove Ignitor Wand and extinguish while continuing to hold Red Button.
CONTINUE TO HOLD RED BUTTON for 20-30 seconds after Burner has been lit.
This will allow thermocouple to reach operating temperature and keep valve open.
Set Ball Valve on LP Tank to 1/2 open.
Repeat this procedure for the Second Burner.
Safety Valve