DOC. N. CIMATICII
REV. 7
ED. 08.2021
Chapter 7. MAINTENANCE
7.1 Precautions for maintenance operations
WARNING:
The Food and Drug Administration (FDA) has issued directives prohibiting the use of oil and lubricants
containing polychlorinated biphenyls (PCB) in, around or on food processing equipment.
Before servicing the machine, turn OFF the main switch and remove the plug. Before removing the cover
(9 - Fig. 2)
do not forget the following: if the machine was powered off at least 1 hour ago, the rotary
sealing head may still be hot enough to represent a burning danger.
7.2 Chain Tension and Regular Maintenance
Check as follows at regular intervals: - the tension of the conveyor chain off of the white plastic chain
guides should be no more than 0.500”
-
0.750” at the middle of the CiMatic II
To tension the chain follow these instructions:
-
Remove end cover (1- Fig. 11)
-
Loosen up the two carriage bracket screws (2 - Fig. 11) on each side of the machine
-
Loosen two locking nuts (1 - Fig. 12) and turn the nut (2 - Fig. 12) clockwise to tension the chain.
It i
s imperative that both sides are done the same amount. Measure to be sure…..
-
Tighten the two locking nuts (1 - Fig. 12)
-
Tighten the two carriage bracket screws (2 - Fig. 11) on each side of the machine
-
Replace cover
Figure 11
Figure 12
Содержание CiMatic II
Страница 2: ...DOC N CIMATICII REV 7 ED 08 2021...