14

15

EN

EN

•  Add the tablets to the solution one tablet at a 

time.

•  Shake the bottle in between and keep adding 

tablets to the water until the solution turns 

from wine red to blue, record the number of 

tablets as you go.

•  Using the data table supplied with your kit, 

match up the number of tablets with the hard-

ness. You will need this fi gure when program-

ming your water softener in the next section of 

this manual.

9. Switching on for the fi rst time

•  Check that the 

inlet hoses and outlet hoses 

or 

couplings

 are 

properly connected

 i.e. 

inlet-to-inlet, outlet-to-outlet.

The 

by-pass arrangement (see page 09) 

should be 

in the open position

 in example:

• 

the inlet-

 and 

outlet valves closed

 (E), (C)

•  Check that the 

by-pass valve

 (D) open

•  Check that the 

mains stop valve

 (F) open.

•  Check that the 

Brine Cabinet 

(G) contains 

salt.

•  Check that the 

water softener

 is 

connected 

to the drain

 (H) and the 

overfl ow pipe

 is be 

linked to each other 

connected

.

Note:

 The drain and overfl ow must not be 

linked to each other.

•  Gently open the 

inlet valve (C)

 so that water 

fl ows into the 

resin vessel.

•  Turn 

ON

 the power, you will hear the valve 

move quietly into the start position. When 

the positioning process has been completed 

(which can take up to 5 minutes) you will 

hear the movement stop,

 the valve has now 

reached its start position

 in preparation for 

the programming procedure.

•  Close the 

by-pass valve

 (D).

•  Gently open the 

outlet valve

 (E).

•  Check for leaks, take corrective action to stop 

leaks if required.

•  Your 

water softener is now on line

 and you 

may start the valve 

programming procedure 

set out in the next section of this manual.

4. Operation

4.1 Function

Capacity requirement-dependent of the unit 
controller: 

The unit operates according to the principle of intel-

ligent regeneration. The average capacity level of 

each model is preset and updates automatically to 

the actual consumption within 14 days.

The presetting is appropriate for the most common 

applications. It is not necessary to adjust the unit 

for individual requirements.

Intelligent quantity-dependent regeneration

When  the  unit  is  started,  the  available  supply  of 

softened water is programmed (depending on the 

hardness of the water).

At  a  user-defi ned  time  (e.g.  at  night),  the  unit 

checks whether the remaining supply of softened 

water is suffi cient for the following day. If this is not 

the case, the softening column is regenerated by 

only the exact percentage necessary to fully reple-

nish the supply of softened water to 100%.

Note:

 With intelligent regeneration, the remaining 

supply of softened water is not wasted.

This  intelligent  regeneration  method  is  possible 

because of the precision fl owmeter, which is able 

to adjust the amount of brine required for partial re-

generation. The consumption of regenerative and 

water is reduced to the required minimum.

In the event of a power failure, the data and the 

time are retained (for approx 72 hours).

The unit is optionally equipped with a device that 

disinfects the ion exchange resin during the rege-

neration. A spring-loaded non-return valve (18) is 

optionally available (see page 5).

Automatic regeneration triggering:

This is an optional setting - not as standard on all 

softeners.

4.2 Operation

Setting the Type of Salt used

To operate effectively, your water softener must be 

set to the type of salt you intend to use in the sys-

tem. 

Tablet salt is suitable.

Pressing the [SET] button will return the display to 

the Normal Operation mode. Programming is now 

complete  and  no  further  adjustment  of  the  water 

softener is required.

Remember to check the salt and water level in the 

brine cabinet weekly.

connect
jack plug 
here

Lift off this cover and connect the 

jack plug of the lead to the 

control box behind the front panel

Charge Bar

Having set the display on the control facia, you will 

notice that during normal operation there is a char-

ge bar running along the bottom of the display. This 

charge bar shows the percentage of water softener 

capacity remaining since the last regeneration. Im-

mediately following a regeneration, the charge bar 

returns to 100%.

Resetting the display during operation.

If the time is to be adjusted during normal opera-

tion, press any key to illuminate the display, press 

the [SET] key once. The display will fl ash and indi-

cate present time. Using the keys will alter the time 

as described on page 7.

Power loss

The  AMECS  system  will  maintain  the  individual 

programming parameters of the water softener for 

up to 72 hours.

If the power cut lasts longer than 72 hrs, the con-

trol will fl ash “00:00“ when power is returned to the 

control. The unit will continue to keep time from the 

moment power is restored. In this situation the time 

of day will need to be reset.

Flow indicator

During normal operation, a fl ow indicator will fl ash 

on the display at a rate of one litre per pulse when 

water is passing through the softener.

Cleaning

Your water softener may be cleaned using a damp 

cloth and a mild detergent. Do not use bleaches, 

solvents  or  spirits  as  they  may  damage  the  sur-

faces.

Manual regeneration [recharge] button

Under normal operating conditions your water sof-

tener will regenerate automatically and you should 

not normally have to regenerate the unit manually. 

If however a manual regeneration is required then 

follow the procedure set out below.

1.  Press any key to illuminate the display.

2.  Momentarily pressing the button (symbol 

underneath the display and furthest to the 

right) will illuminate Recharge Tonight on the 

display and perform a regeneration at 2.00 

a.m. regar less of the remaining water softe-

ner capacity.

3.  If the button is subsequently pressed, this 

will clear the Recharge Tonight indicator from 

the display and cancel the Recharge Tonight 

feature.

4.  If the [recharge] button is pressed down 

for six seconds, the controller will fl ash the 

Recharge display and immediately com-

mence the regeneration cycle which cannot 

be cancelled.

Adding regenerative

Refi ll the salt no later than when 

SALt

 is indica-

ted on the display or 150mm above the base of the 

softener.

Acknowledge - low SALt alarm:
NOTE:

 This function is optional - not standard on

all models.

Open the cover (4). Pour regenerative into the

storage area (5).

Press [SET] and hold until the SALt display goes out.

Refi ll the unit in such a way that no dirt can get 

into the storage area (5) (if necessary, clean the 

packages containing the regenerative before use).

Clean the storage area or brine cavity (6) with
clean water if it gets dirty.

Salt usage

Your water softener is controlled by a microproces-

sor which constantly monitors water usage.

The system will build up a history of your water re-

quirements and calculate the most economical re-

generation pattern. This will ensure a constant sup-

ply of softened water whilst maintaining high levels 

of water and salt effi ciency. As your water softener 

uses a proportional brining system, more frequent 

regenerations do not necessarily mean high water 

/ salt usage.

Increase in number or residents

Sudden changes in your water usage should not 

affect your water softeners performance. If howe-

ver, the number of guests staying with you incre-

ases, you will notice that the water usage patterns 

will  alter. This  may  cause  your  water  softener  to 

regenerate more often than normal. As the water 

usage returns to its normal level, the number of re-

generations will also return to normal.

Cabinet Water Level

During normal operation the water level inside the 

water softener cabinet will rise and fall as required 

by the regeneration process. If the water softener 

is used within the specifi ed operational parameters 

the water level should not reach the overfl ow con-

nection.  If  however  an  overfl ow  situation  occurs 

please  refer  to  the 

troubleshooting section on 

page 17 to diagnose

 the problem.

OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd   14-15

02/10/2012   09:49

Содержание Access 10

Страница 1: ...bau und Bedie nungsanleitung stets griffbereit aufzubewahren vor der Ausf hrung von Ar beiten am Ger t vollst ndig durchzulesen und zu beachten Unsere Merk bl tter und Druckschriften sollen nach beste...

Страница 2: ...the hardness of blended water 16 5 Maintenance 16 5 1 Maintenance work 16 5 2 Operator responsibilities 16 5 3 Maintenance wearing parts 16 5 4 Disposal 16 6 Fault finding 17 6 1 Trouble shooting Guid...

Страница 3: ...pplication Cillit Access is desig ned for softening or partially softening domestic water in accordance with the relevant regulati ons All other use is strictly forbidden and your own responsibility 1...

Страница 4: ...ally dependent on the hard ness of the supply and amount of water used The default time of day when this is to occur is 2 00am To alter this setting use the UP DOWN keys Pressing the SET key once ente...

Страница 5: ...ion protection Attention Water pressure must never exceed the unit s maximum of 5 0 bar UK 8 0 bar EU If the network water pressure is higher than 4 0 bar UK 6 0 bar EU or you are unsure about pressur...

Страница 6: ...ater softener In case of low sodium diet follow the local department of health s advice concerning the use of softened water for drinking Note Water that is used for mixing powdered milk for babies mu...

Страница 7: ...d or restricted in any way as this will cause an overflow from the bri ne cabinet Frost protection If the drain hose or connecting pipework is likely to be subject to temperatures below 0 C it must be...

Страница 8: ...l operation there is a char ge bar running along the bottom of the display This charge bar shows the percentage of water softener capacity remaining since the last regeneration Im mediately following...

Страница 9: ...aced within the prescribed maintenance intervals in order to guarantee functionality and fulfil the warranty conditions The water softener should be serviced once a year Wearing parts may only be repl...

Страница 10: ...e home position is not detected within 10 minutes the main display will show an Err 1 message to indicate a controller error and an audible alarm will sound The error condition can only be cleared by...

Страница 11: ...ox kg 65 Tested with HiFlow connection available in option 7 2 Cillit Access 15 15 Bio Cillit Access Unit 15 15 Bio Nominal connection outside thread BSP DN 20 Nominal flow rate in accordance with EN...

Страница 12: ...The company BWT UK Ltd declares that the product domestic water softener with the following specifications Trade name of product Type of product Model Cillit Access 10 10 BIO 10 litres Cillit Access...

Страница 13: ...37 4 3 H rtegrad des Mischwassers festsetzen 38 5 Wartung 38 5 1 Wartungsarbeiten 38 5 2 Betreiberverantwortung 39 5 3 Wartungs Verschlei teile 39 5 4 Entsorgung 39 6 Betriebsst rungen 40 6 1 Leitfad...

Страница 14: ...deckung abgenom men wurde Beachten Sie Benutzen Sie bei Bedarf Schutzkleidung Beachten Sie Zus tzliche Information f r die Bedie nungsperson 1 4 Bestimmungsgem e Verwendung Die Weichwasseranlage ist d...

Страница 15: ...egelm igen Abst nden rege nerieren abh ngig von der H rte und der Menge des zugef hrten Wassers Die Standardzeiteinstel lung daf r ist 2 Uhr Fr h Um diese Einstellung zu ver ndern benutzen Sie die UP...

Страница 16: ...wankungen durch benachbarte elektrische Systeme darf den Ma ximalwert wie er in EN 61000 6 3 spezifiziert ist nicht berschreiten Datenanlyse des Rohwassers in Ihrer Gegend Ein Dauerbetrieb des Wassere...

Страница 17: ...F rderh hen systeme Der Wasserenth rter kann nach Bedarf mit einem Hochvolumenf rderstrom Satz und flexiblen Hochvolumenf rderstromschl uchen passend f r 22mm Leitungen geliefert werden f r 15mm Leitu...

Страница 18: ...laufschlauch zu einem Standrohr oder Ablauf Der Luftspalt muss mindestens 20 mm betragen Weichwas ser hat keine potenziellen Schadwirkungen auf eine Kl rgrube Sie k nnen den Abfluss auf bis zu 9m verg...

Страница 19: ...das die Solemenge an den Bedarf f r eine Teilregeneration anpasst Der Konsum des Rege nerierungsmittels und Wassers wird auf das Mini mum reduziert Im Fall eines Stromausfalls werden Daten und Ze ten...

Страница 20: ...schneideventils V dem gew nschten Wert an H rte in ppm Anzahl der Personen 02 03 04 05 06 150 8 7 6 5 4 200 7 6 5 4 3 250 6 5 4 3 2 300 5 4 3 2 1 350 4 3 2 1 1 400 3 2 1 1 1 Anzahl der Tage zwischen...

Страница 21: ...ten Sie einen Regenerationszyklus indem Sie den manuellen Regenerationsknopf RECHARGE dr cken und l nger als 6 Sekunden gedr ckt halten Achtung Funktioniert Ihr Wasserenth rtungsger t nicht so wie es...

Страница 22: ...ca kg 40 Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 2 Cillit Access 15 15 Bio Cillit Access Typ 15 15 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 156...

Страница 23: ...Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 4 Cillit Access 25 25 Bio Cillit Access Typ 25 25 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 1680 Betrie...

Страница 24: ...nien Leitf den konstruiert produziert und endgefertigt wurde 2006 95 EG Richtlinie f r Niederspannung NSR 2004 108 EG Richtlinie f r elektromagnetische Vertr glichkeit EMV Beachten Sie F hren Sie ohne...

Страница 25: ...9 02 201058 E Mail cillichemie cibemi it Cilit S A E 08940 Cornell de Llobregat Barcelona P I del Este Silici 71 73 Tel 34 93 4740494 Fax 34 93 4744730 E Mail cilit cilit com Cillit Direction Commerci...

Отзывы: