Comfort units

Coanda effect cassette

COADIS LINE 900

Electrics box

 

   Large ABS electrics box, with a hinge to keep it open and 

screw closure.

 

   Protection  rating:  IP20.

 

   Terminal block on DIN rail in accordance with EN 50022, 

depth 7.5 mm.

 

   Junction block located with tension clamp. Cross section 0.5 

to 2.5 mm² - Max current: 24A – Shock resistance: 8 kV.

 

   Cable routing for customer electrical connections.

Fresh air supply sleeve

 

   Ø 100mm sleeve integrated into the casing with removable plug. 

Air filter

 

   

EPURE function 

●   a protected air stream which prevents particles present in the 

suspended ceilings from being drawn in,

●   uniform  treatment  of  the  room  thanks  to  optimised  diffusion 

(Coanda effect) and an adapted mixing rate,

●   local filtration by high efficiency filter medium effective on fine 

particles up to 2.5 microns,

  ●   filter area 10 times greater than the intake grille surface,

●   no discharge from the filter during replacement thanks to the 

folded filter medium with heat-sealed lateral inserts to make 

it more rigid,

   ●   longer  service  life  compared  to  a  conventional  flat  filter, 

thanks to its high retention capacity,

●   low energy impact, 

●   fire rating: M1,

  ●   no release of glass fibres,

  ●   100% incinerable at end of life.

Or 

●   flexible filter medium made of regenerative polyester fibre,

 ●     efficiency class EN 779: G3,

   ●   fire rating: M1,

  ●    rigid metal frame, 

   ●   accessible via the hinged air recovery grille. 

Standard wiring diagram  

without control

 

  

2-tube and 4-tube application

: 7320074.

 

   

2-tubes + electric application

: 7320075.

Securing the device

Open mounting brackets, factory-fitted, made from galvanised 

steel, 15/10th thick, with check valve for securing the threaded 

rods during fitting and levelling.

Packaging

 

  Strapped cardboard crate for the casing.

 

  Fitting template and direction of assembly printed on the box.

 

  Visual return/supply air interface delivered separately in its 

own protective cardboard packaging.

 

  Delivered on a plastic-wrapped pallet.

Controls

 

   RTR-E  electromechanical  thermostat  range.

 

   V30  electronic  range.

 

   V300  electronic  range.

 

   V3000 networked electronic range (KNX).

 

   V-Lon networked electronic range (LON).

Optional accessories

 Delivered separately:

●   self-adjusting fresh air module kit:

 

- 15/30/45 m3/h flow rates,

 

- 60/75/90 m3/h flow rates,

●   Ø100/125 mm adapter for fresh air sleeve,

●   resilient mounts,

●   finish frame for STAFF ceiling,

● fresh air pack:

 

- R1: fresh air managed via presence sensor,

 

-  R+: fresh air management via CO2 sensor (max. air flow  

90 m3/h recommended, network balancing system not 

supplied by CIAT).

Option (contact us)

●   Hydraulic  coil  with  blades  protected  for  use  in  harmful/

corrosive atmospheres (coastal locations, or areas close to 

chemical industries).

Содержание CDL922

Страница 1: ...ual 360 diffusion model Coanda effect diffuser across 360 The Coadis Line is available as A 2 tube system with heating or cooling mode A 2 tube 2 wire system with heating or cooling cooling electric m...

Страница 2: ...elected G3 EP EPURE filter G3 G3 filter HEE 2 10V Energy efficient motor 2 10V control HEE ON OFF Energy efficient motor 3 speed control AC 5 speed asynchronous motor 2000W For 922 3000W For 932 and 9...

Страница 3: ...on 80 C 2 tube application 70 C 2 tube 2 wire application 55 C min air flow rate 200m3 h min cold water inlet temperature 6 C Electric heater 2 tube electric system 230 1 50 single tube electrical ele...

Страница 4: ...cinerable at end of life Or flexible filter medium made of regenerative polyester fibre efficiency class EN 779 G3 fire rating M1 rigid metal frame accessible via the hinged air recovery grille Standa...

Страница 5: ...sing 4 threaded rods either 6 mm or 8 mm in diameter not supplied which are fixed to the unit s 4 support brackets using resilient mounts or a nut washer assembly positioned on either side of the moun...

Страница 6: ...g Unit Grid Total 922 35 10 45 924 35 45 932 40 50 932SP 40 50 934 40 50 934SP 40 50 900 240 103 5 75 27 205 67 60 40 145 32 S1 S E1 E 981 938 21 5 G1 2 heating manifold G3 4 cooling manifold Condensa...

Страница 7: ...Valve and motor assembly 24V or 230V Heating cooling assembly for valves with 3 point motors Heating cooling assembly for valves with thermo actuators PN16 15 230Vac 230Vac PN16 15 Outlet O ring O ri...

Страница 8: ...ew European ErP Energy related Products directive applies to all manufacturers of equipment fitted with a fan with a power input of between 125 watts and 500 kilowatts inclusive in this directive the...

Страница 9: ...tube system Hot or cold water coil G3 4 G3 4 G3 4 4 tube system Cold water coil G3 4 G3 4 G3 4 Hot water coil G1 2 G1 2 G1 2 Condensate drain pump TECHNICAL CHARACTERISTICS Maximum flow rate 100 l h...

Страница 10: ...XB Bornier de raccordement Terminal block Note Commande du ventilateur si gestion 0 10V thermostat client Fan control if 0 10V control customer s thermostat Condensate drain pump wiring Vert Jaune Gre...

Страница 11: ...s box side Code Serial number Description of the unit Rated motor output Motor rotation speed Coil type Wiring diagram reference Motor speed wiring Maximum service pressure Electric heater specificati...

Страница 12: ...peed selection With 0 10 V control adjustment via the controller with 3 speed on off control adjustment via the control unit option Note For more information refer to instruction manual N11 47 speed s...

Страница 13: ...2000 W 2R 5 4 V4 990 5 570 4 460 7 240 49 31 6 0 V3 845 4 990 3 960 6 460 46 28 7 0 V2 700 4 320 3 400 5 590 43 24 8 5 V1 550 3 610 2 760 4 620 40 20 10 8 932 V5 1090 7 600 5 690 9 030 50 33 3000 W 3...

Страница 14: ...00W 3000W Size 922 932 932SP 922 932 932SP Air handling section auxiliary pan Code 7344019 7344020 7351396 7344013 7344014 7351314 Diffusion interface VISUAL 360 with EPURE filter Code 7335537 VISUAL...

Страница 15: ...d flexible connections EPDM pipe PN10 stainless steel braid length 300 mm Female rotary couplings on both sides Code 2 x 5202298 All 2 way valve Two M1 9 mm thick insulated flexible connections EPDM p...

Страница 16: ...the unit or open the suspended ceiling Smooth and free from corners where dust could accumulate the single slot diffusion system enables quick easy cleaning The VISUAL 360 interface will be primarily...

Страница 17: ...leaks for electrical safety and for the proper protection of components The fresh air enters through a smooth metal sleeve with no flow control or via a self adjusting collar and module assembly desig...

Отзывы: