12
D1
D1 PI N
RS485-
VI DEO+
VI DEO-
RS485+
AC24V
AC24V
Fi gur e 13
Fi gur e 14
Fi gur e 15
RED CONNECTOR
( POWER I N)
BLACK CONNECTOR
( RS485 CONTROL I N)
VI DEO OUT
RED LI NE( AC24V I N)
BLACK LI NE( AC24V I N)
ORANGE LI NE( RS485+)
YELLOW LI NE( RS485- )
10)
Insert attachment plug in aluminum alloy into socket D2 (Figure 15-1).
D2: To Bl ower / Heat er
Devi ce( AC24V)
Figure 15-1
11)
Based on the coding switches shown as Figure 2, set up the protocol used by the
camera and the baud rate as per the state according to Table 2. Check the address of
the camera to see if it is matched with that you need. If not, set the address of the
dome camera at corresponding position as per Table 1.
12)
Rotate the vitreous cover on dome counterclockwise and take it out. Note: if
Fixed the Speed Dome Camera in the aluminum alloy ball, you must take out the
vitreous cover on dome. Otherwise, it will effect picture quality
. (see Figure 16)
13)
Aiming the “MARK” on the ball at the notch on the pedestal, push the ball upward to
the end and rotate clockwise until it is clicked, then mount the vitreous cover by
rotating it clockwise (as shown on Figure 17), and mount the cover plate of the
bracket at last (see Figure 18).
The product have 4 alarm input:
ALM-4 Channel 4 collector alarm input: 4
ALM-3 Channel 3 collector alarm input: 3
ALM-2 Channel 2 collector alarm input: 2
ALM-1 Channel 1 collector alarm input: 1
GND Common collector alarm
One RELE out:
COM Common collector alarm out
NC Close collector alarm out
NA Open collector alarm out
N°1 – channel alarm activation, then call.N°29 preset
N°2 – channel alarm activation, then call.N°30 preset
N°3 – channel alarm activation, then call.N°31 preset
N°4 – channel alarm activation, then call.N°32 preset
N.B.: Presetting the preset of No. 29,30,31,32 then the alarm
could respond.