MS100 + FCMS
Geared-motor MS100 with PCM100 central unit
and magnetic limit stop sensor FCMS
FCMS
Geared-motor MS200T(380V) with magnetic
limit stop sensor FCMS
PCM130
PCM130 central unit
FX30D / FX40D (TX)
Transmitting photocell (Channel
A
)
FX30D / FX40D (RX)
Receiving photocell 1 (Channel
A
)
FX30D / FX40D (TX)
Transmitting photocell 2 (Channel
B
)
FX30D / FX40D (RX)
Receiving photocell 2 (Channel
B
)
LAMP230G
230Vac electronic flasher
BIRD
VHF receiver with antenna
SC1
Key selector
FCMM
Magnetic opening limit stop
FCMM
Magnetic closing limit stop
CRP
Plastic rack
ONLY PCM100:
PCM100 central unit can be installed inside the geared-motor MS100 by the provided screw, or it
be fixed at the wall by two screw anchors.
In both cases, you must fix the cover to the base by the screw furnished with the central unit.
P
C
M
1
3
0
P
C
M
1
0
0
23
Installation
22
PCM100 / PCM130 - User Manual
Trimmer A: Opening time
Voltage fuse (250Vac 500mA)
Trimmer B: time of pause
Setup Dip-Switch
LED closing limit stop status
LED opening limit stop status
LED photocell 2 status
LED photocell 1 status
LED STOP Status
Opening/closing limit stop
clamps, to use when central
unit is installed outside motor.
P2: partial opening
P1: total opening
A
LED Button P2
LED Button P1
Photocells and 24 Vac clamps
BIRD and commands clamps
Flasher
230Vac
*autoapprendimento
codice radiocomando
Motor
2.2.1
Connections (PCM130)
1
2
3
4
5
6
7
8
9 10 11 12 13
14 15 16 17 18
19
20
21
10 - Common
11 - Pulse STOP (NC)
12 - Pulse A (NO)
13 - Pulse B (NO)
14 - NC
15 - Common
16 - NC
17 - 24V~ max 100mA
18 - 24V~ max 100mA
1 - Motor Input
2 - Motor Output
GEARED MOTOR
230V~ 550W max
6 - Pole 1
7 - Pole 2
FLASHER 230V~
PHOTOCELLS
(FX30D - FX40D)
8 - Pole 1 (clamp 1 BIRD)
9 - Pole 2 (clamp 2 BIRD)
BIRD ANTENNA
19 - Opening limit-stop
20 - Limit-stop common
21 - Closing limit-stop
LIMIT-STOP
Use this clamps only if
central unit board is
installed outside of the
geared-motor.
3 - L1
4 - Ground
5 - N
POWER SUPPLY
230V~ ±10% 50Hz
COMMANDS
2.2
Board Description (PCM130)
learn remote
control code
2.3
Example of installation
7
2
3
8
6
1
4
5
9
10
11
Provided
screw
PCM100 central unit installed
inside of MS100 motor
Centrale PCM100 installata a muro
FCMS
Limit-stop
sensor
1
2
3
7
8
6
9
10
11
4
5
1A
1B
Channel
A
Channel
B
1A
1B