CI Wireless Inc.
Description of the Control Module
MirrorCell Select CDR812 Manual
Rev. X1
6-15
6.11.7 Miscellaneous Alarm Configuration Parameters
6.11.7.1 Configuring the External Alarms
The external alarms can be configured active-low or active-high. Use the following
command to configure these alarms:
SET
EXT BC <enter>
B refers to pin 1, read from EX1, and C refers to pins 2, read from EX2.
B, C = 0
means that no voltage is an OK condition
B, C = 1
means that a high voltage is an OK condition.
Note:
The write access to these parameters is valid only if you are logged in with a read-
and-write access password, or if you are sending an SMS message with read and write
access.
Designation
Attribute Read
Write
Format
Comments
External alarm
EXT
X
X
BC
B, C = 0 Alarm active low.
pin configuration
B, C = 0 Alarm active high.
Repetition cycle
RCA
X
X
NNN
Amount of time the repeater waits before
alarm
3 digits
retransmitting unconfirmed alarm
Minimum alarm
MAR
X
X
NN
NN is from 0 to 99 minutes.
repetition time
2 digits
Maximum
MNR
X
X
NN
Maximum number of RCA attempts.
number of
2 digits
repetitions