Description of the Control Module
CI Wireless Inc.
MirrorCell Select CDR812 Manual
6-6
Rev. X1
6.10.2 Status Parameters
Designation
Attribute
Read
Write
Format
Comments
Amplifier downlink AMD
X
BB
First digit: channel 1 status
status
Second digit: channel 2 status
0 is OK
1 is ERROR
- is channel not installed
Amplifier uplink
AMU
X
BB
First digit: channel 1 status
status
Second digit: channel 2 status
0 is OK
1 is ERROR
- is channel not installed
Status of
COM
X
XYZW
X is status of communication with
communication
channelizer 1 UL (reverse)
Channelizers to
Y is status of communication with
Controller
channelizer 2 UL (reverse)
Z is status of communication with
channelizer 1 DL (forward)
W is status of communication with
channelizer 2 DL (forward)
0 is OK
1 is ERROR
- is channel not installed
Door status
DOO
X
B
0 = closed; 1 = opened
External pin 1
EX1
X
B
Status of external pin 1
status
0 is OK
1 is ERROR
External pin 2
EX2
X
B
Status of external pin 2
status
0 is OK
1 is ERROR
Power 1 status
PW1
X
B
Status of Power 1
0 is OK
1 is ERROR
Power 2 status
PW2
X
B
Status of Power 2
0 is OK
1 is ERROR
Synthesizers
SZD
X
BB
First digit: channel 1 status
downlink
Second digit: channel 2 status
0 is OK
1 is ERROR
Synthesizers
SZU
X
BB
First digit: channel 1 status
uplink
Second digit: channel 2 status
0 is OK
1 is ERROR
Temperature
TEM
X
B
0 indicates operating within limits
1 indicates operating out of limits
Содержание CDR801