Chapter 8           Quality Warranty

1) Warranty Period Under Normal Conditions

 We provide guarantees for repair, replacement and return of the 

purchase in 1 month from the date of use.

 We provide guarantees for repair and replacement in 3 months 

from the date of use.

 We provide guarantee for repair in 12 months from the date of 

use or 18 months from the date of ex-factory.
2) The purchaser enjoys life-long paid service whenever and 
wherever he uses a motor soft starter made in our company.
3) Service in the following cases, even within the warranty period, 
shall be charged to the purchaser:

 Problems caused by mal-operation in violation of this manual, 

or caused by unauthorized repair or renovation.

 Problems caused by improper use of soft starter that is off 

standard and requirement;

 Malfunction or damage caused by improper transit or storage 

after purchase;

 Induced failure or aging of the device due to poor ambient;
 Malfunction or damage caused by fire, flood, thunder, 

earthquake, abnormal voltage or other natural disasters;

 Unidentifiable nameplate, mark and ORD number due to 

intentional spoilage;

 Delayed or unsatisfied payment in violation of purchase 

appointment;

 Fail to give an objective description on the use of installation, 

wiring, operation, maintenance or else;
4) Defective products should be sent to us for repair, replacement 
and return, which can be proceeded only after verifying the 
burden of liability.
5) In case there is any quality problem or accident, we merely 
promise to bear the above-mentioned responsibilities. If a user 
needs more guarantees for liabilities, please assure on the 
insurance company voluntarily.

Appendix

1

Varieties of Application Loads

This soft start can meet the requirements of most heavy loads. The table below is for 
reference only.

Varieties of 
Application Loads

Start Ramp 
Time (S)

Stop Ramp 
Time (S)

Inception 
Voltage (%)

Voltage Start 
(Maximum Current-
limiting Value)

Current-
limiting 
Start

2) RS485 Communication

This soft starter can be connected to PC, PLC or other hosts through a 
built-in RS485 standard interface to perform serial communication 
(COM). The host can give a command to start or stop the soft starter, 
monitor the operation state of the soft starter and modify its functional 
parameters. For details of this communication, please refer to RS485 
Operating Manual. By using RS485 COM of the soft starter, remote 
operation can be realized via a computer such as input of run command, 
management on operation state, and one-step writing of functional codes 
for multiple soft starters to realize simplified operation while inputting 
functional codes.

Main Functions of RS485 COM:

 Inputting start or stop command;
 Monitoring operation status;
 Real-time tracing (i.e., table display of running information);
 Once-step reading and writing of functional codes, and saving to the 

file;
A separate agreement shall be signed between the two parties of us for 
communication software.

Centrifugal Pump

Ball Grinder

Fan

Piston Type 

Compressor

Light Load Motor

Elevating 

Mechanism

Mixer

Crusher

Screw Compressor

Spiral Conveyor

Leather Belt Conveyer

Heat Pump

Содержание ZJR1 Series

Страница 1: ...ZJR1 SERIES SOFTSTART USER S MANUAL...

Страница 2: ...ty Instructions 1 1 2 Product Inspection upon Arrival 2 1 3 Demonstration of the Specifications Label and Model 2 1 4 Outline of the Product 3 1 5 Models and Specifications 4 1 6 Technical Indications...

Страница 3: ...ails in the input and output ports with insulated sheath or tape When the motor soft starter is under remote control do lock the keyboard control to avoid accidence due to error operation Do cut off t...

Страница 4: ...W Nameplate Base Circuit Board Cabinet Connect to the bypass contactor L21 L22 L23 Input Terminals of Power Supply R S T Operation Panel Base Control Terminal Connect to the motor U V W Circuit Board...

Страница 5: ...rameter setting 12 Load shortcircuit protection 13 Autorestart or incorrectwiring protection 14 Incorrect wiring protection of external control stopterminals Ambient Structure Place to be used Altitud...

Страница 6: ...cuit power supply or install an electromagnetic contactor between the input terminals R S T and the power supply to run or stop the motor soft starter Do select RUN or STOP keys on the operation panel...

Страница 7: ...k Terminal Name Functional Description Bypass Output Operation Output Delayed Switch on 01 and 02 after soft starter is completely started to control bypass contactor 03 and 04 indicate programmable r...

Страница 8: ...Start Common Port Switch K on motor starts switch K off motor stops Chapter 2 Installation and Wiring Instantaneous Stop Stop Start Common Port Instantaneous Stop Stop Start Common Port 2 3 6 Relay N...

Страница 9: ...ne stops completely 2 This key also performs the function of failure state resetting When REAdy is displayed press this key to set the manual When P0030 is displayed repress this key When flashes pres...

Страница 10: ...regardless of successor failure Note H1 H9 refer to save 9 recently occurred failure tips in a recursive way If entering setting mode in none soft start stop mode you may get tips Press then press to...

Страница 11: ...he current limiting value code P3 indicating current mode enabled to raise the torque Be sure the motor rotates in the correct direction Only after making sure there is no anomaly can the motor be put...

Страница 12: ...error report P2should be set to thismode if thesoft starter adoptsone to multi wiring method To extend the servicelife of softstarter free stop mode isgenerally preferred ifthere is no needto adopt so...

Страница 13: ...oltage but not through the mechanical control over time t regardless of whether the motor is accelerated steadily Therefore if there is a light load the starting time will tend to be less than the set...

Страница 14: ...rammable output external terminals changes from open toclose that is reversed phase output Flexible use ofprogrammable relay output functions cansimplify external control logic circuit Chapter 5 Descr...

Страница 15: ...the decisiondatum deviation willbe enhanced Overcurrent Starting ProtectionTime Thisrefers to theprotection time thatis successively 5 timeslonger than themaximum working currentset by thecode P4 See...

Страница 16: ...atment Fault cleared Faults such as undervoltage overvoltage overcurrent instantaneous terminal open etc have been eliminated Everything turns to normal and now the LED ready lights up indicating the...

Страница 17: ...tableabove are themaximum values ofa soft starter Generally ratedcurrent matching themotor that hassame power shouldnot excess therated current values listedin this table If outline sizesdiffer from t...

Страница 18: ...uality problem or accident we merely promise to bear the above mentioned responsibilities Ifa user needs more guarantees for liabilities please assure on the insurance company voluntarily Appendix 1 V...

Отзывы: