background image

40

Tr

ouble

   

    

    

Shooting

12-3-E. HOT GAS V/V WIRE DISCONNECT

Symptom

Ice is made, but does not fall off the fingers.

Cause of Defect

If Hot Gas does not flow properly, may lead to the Axle Coupling to break.

AS Procedure

1) Check power “ON” or “OFF” from Test Board (LED4).
2) Change Wire or check Wire connection.

How to Diagnose
Connect Test Board and press the Ice Re-
lease Button.

Check to see if it is functioning.

1

2

Voltage : AC 220V

Содержание IGUASSU ICE

Страница 1: ...Technical Repair guide for ChungHo Iguassu ICE call 888 758 1234 for further technical support IGUASSU ICE Technical Manual...

Страница 2: ...ram 6 Product Specification 7 Installation Precautions 8 Relocation Installation Precautions 9 Installation 10 Usage 10 1 Display 10 2 Water Dispensing Buttons 10 3 Operational Beep 10 4 Select Desele...

Страница 3: ...ff Econo Mode Button Ice Full Display Water Full Display Hot Water Lock Button Hot Water Selecting Button Ice Dispensing Button Water Dispensing Nozzle Water Dispensing Push Button Cold Water Selectin...

Страница 4: ...s 1 2 INTERIOR Top Cover Ambient Water Tank Cold Water Tank Hot Water Tank Wire Condenser Compressor Filters Booster Pump Ice Making Unit Ice Storage Front Upper Panel Drip Tray Drainage Valve Drainag...

Страница 5: ...5 Designation of Components Hot Water ON OFF Switch 1 3 BACK Drain Outlet Waste Water Outlet Water Source Inlet Power Cord...

Страница 6: ...d produces only the purest ice by supplying purified water to the ice mak ing unit The freezing point principle states that purest water freezes at 0 while non pure water will freeze at a temperature...

Страница 7: ...water cold water hot water and ice from the same product Standard hot water safety function Hotwaterlockingfunction Hotwaterautomaticselection Releasefunction Setting the hot water locking function u...

Страница 8: ...has a reset function which shortly after selecting hot or ambient water will automatically switch the cooler into cold water mode Separate water delivery from a single spout Ambient water cold water a...

Страница 9: ...mize convenience Environment Friendly Coolant The Iguassu Ice has adopted an environmentally friendly cooling system in the new R 134a a coolant that will not add to the problems of ozone layer destru...

Страница 10: ...10 3 Exploded Diagram 3 1 OVERALL DIAGRAM Water Dispensing Solenoid Valve Drainage Valve Drainage Switch TR...

Страница 11: ...Diagram 11 3 2 ICE MAKING DEPARTMENT Inlet Solenoid Valve Sub Tank Ice Full Sensor TX Ice Full Sensor RX Synchronous Motor Camshaft Ice Outlet Guide Circulation Pump Cold Water Sensor Cold Water Leve...

Страница 12: ...ColdDrain Water Dispensing Ice Dispensing Level Sensor Ambient Water Tank Cold Water Tank Ice Making Unit Ice Storaging Unit Hot Water Tank Membrane Post Carbon Sediment Booster Pump UV optional 12 4...

Страница 13: ...5 Distribution Line Diagram 13...

Страница 14: ...h month N class 90 1 32 1 13g 1gX12ea one time ice making 1ea cold water tank submerging WIRE CONDENSER TYPE natural convection THERMISTOR Bimetal automatic return Bimetal manual return Overheating pr...

Страница 15: ...mately 8 in between the wall sides and rear surfaces of the product so that ventilation may be smoothly performed for safe operation of product When connecting tubing hose take care so that the tubing...

Страница 16: ...n order to remove the water remaining in the cold water tank tilt the product forward and do so until cold water does not come out Take out the ice by pressing the ICE ice dispense touch sensor button...

Страница 17: ...multi purpose room etc Install the removed water brine line and drained water line separately If drainage dose not function properly due to improper installation then water may flow back toward water...

Страница 18: ...LED ECONO LED Power saving display LED Lights up when setting hot water operation Red Lights up when setting the power saving function Red Lights up when setting the hot water locking function Red HOT...

Страница 19: ...ter hot water lock function is released the hot water function operates by touching HOT ECONO hot water operation power saving selection or HOT hot water dispensing selection touch button 3 HOT hot wa...

Страница 20: ...flash 5 times in one second intervals 1 1 1 2 2 2 3 3 6 Usage 5 ECONO power saving Function Setting Touch the HOT ECONO hot water operation power saving selection touch sensor button Power saving dis...

Страница 21: ...water is selected and it is not used for a given time period the system will automatically switch into cold water dispense mode Default function There is not a separate setting and release method for...

Страница 22: ...e ice making system will produce the ice according to the given water supply Water supply action This refers to an action to supply about 25G 1 of cold water every 50 seconds into ice making mechanism...

Страница 23: ...ror Ice Sensor Error Ice Size Big LED 2 LED 8 LED 14 LED 20 LED 26 Booster Pump ON Ice Detection TX 7 Second Room Temperature Above 130 F Environment Sensor Error Ice Size Medium LED 3 LED 9 LED 15 LE...

Страница 24: ...3 Axle Coupling Replacement 36 4 Water Odor Bad Taste 41 5 Water Leak 42 6 Residual Water 44 7 Dispense Button Malfunction 46 8 Touch Sensor Defect 47 9 Ice Water Full LED Blinking 48 10 Water Full L...

Страница 25: ...26 B Hot Gas Leak 27 C OLC S Defect 28 D Cold Water Level Sensor Defect 29 E Main Sol V V Defect 30 F TRC Sensor Defect 31 G Circulation Pump Defect 32 H Ice Temperature Sensor 33 12 1 No Ice No Cold...

Страница 26: ...mp is working but no Cold Water No Ice 1 Comp is working but back grill is cold 2 Comp is working but the dryer is cold Check temperature 10 min after the Comp has operated Cause of Defect Compressor...

Страница 27: ...Water Sol V V needs to open and shut properly When it is clogged with particles it prevents the Hot Gas Sol V V from shutting off AS Procedure 1 Connect the Test Board and press the Ice Release button...

Страница 28: ...efect Symptom Water tanks do not get full Cause of Defect 1 Mesh clog 2 Defective Pump 3 Defective Sol V V 4 Membrane clog AS Procedure 1 If Mesh Medium Filter are clogged Clean or replace 2 Check to...

Страница 29: ...1 Main OLC S not full above 25 level 2 Water is continuously draining 3 Cold water is not coming out Cause of Defect 1 Sensor will not work properly and will cause water to overflow 2 Sensor will not...

Страница 30: ...Cold tank not full takes approx 5 min Will test 3 times after the third time Test Board LED23 will start blinking 12 1 e Main Sol V V Defect Symptom Cold water is not coming out Cause of Defect Water...

Страница 31: ...Comp is working properly but TRC sensor is defective preventing Ice making Compressor will continue to operate until 40F Cause of Defect If TRC Sensor is defective but Comp is operating for more than...

Страница 32: ...Board Circulation pump defective or Ice tray frozen 2 If Ice tray is frozen may cause Camshaft axle coupling to break Cause of Defect Defective Circulation Pump will cause over freezing thus may caus...

Страница 33: ...t If Ice temp sensor detects 22 F it will cause Circulation pump to be considered defective and stop the Comp When sensor is defective or disconnected system stops making Ice AS Procedure Replace Ice...

Страница 34: ...ck to see if the Ice Full Sensor s are connected prop erly 12 2 A Ice Full Sensor s Defect Symptom 1 Ice is full but does not dispense 2 Ice dispense motor functioning but there is no Ice Cause of Def...

Страница 35: ...Ice button is pressed but blades are not rotating Cause of Defect 1 Motor shaft is not aligned properly 2 Motor may be defective AS Procedure 1 Align shaft 2 Replace Motor How to Diagnose Press the Ic...

Страница 36: ...r freeze and or freeze irregularly thus causing axel coupler to break or not function properly AS Procedure Exchange Ice Full sensor s How to Diagnose Press the Ice button to dispense Ice 2 There is I...

Страница 37: ...t the legs to level the unit Level is provided in the drip pan To remove level use a sharp object to pop out Must be place on top of the unit towards the front How to Diagnose Press the Ice button to...

Страница 38: ...ence in the interval of time of Ice making check the Environment sensor 12 3 c Environment Sensor Defect Symptom 1 Cold water is working properly but there is no Ice 2 Connect Test Board LED22 starts...

Страница 39: ...tion AS Procedure 1 Check for particle build up in impeller by separating Circulation Pump 2 Change Axle Coupling and or Circulation Pump 3 Please remove the tray motor in order to get to the Axle cou...

Страница 40: ...Cause of Defect If Hot Gas does not flow properly may lead to the Axle Coupling to break AS Procedure 1 Check power ON or OFF from Test Board LED4 2 Change Wire or check Wire connection How to Diagnos...

Страница 41: ...water is oily Cause of Defect Cannot be determined due to varying issues from install environment AS Procedure 1 Install Check V V on the drain line to prevent back flush from drain 2 Change Medium F...

Страница 42: ...or Defect Symptom 1 Ambient water is not full 2 Water keeps flowing to drain 3 Water is dripping down from Ice dispense tunnel rotator blade Cause of Defect 1 Sensor will not work properly and will ca...

Страница 43: ...as particles 2 Water is dripping down from Ice dispense tunnel rotator blade Cause of Defect If there are particles stuck in the Main Sol V V may cause the water to drip down from Ice dis pense tunnel...

Страница 44: ...pping from spout Cause of Defect If particles build up inside Sol V V it will prevent the Sol V V from shutting off water from ambient tank and cause it to drip AS Procedure 1 Detach appropriate Sol V...

Страница 45: ...ing on Spout Symptom Water keeps dripping from spout Cause of Defect 1 Assembled improperly 2 There may be an air bubble 3 The diameter of the spout may be defective AS Procedure 1 Check assembly to m...

Страница 46: ...offee dirt etc 12 7 Dispenser Button malfunction Symptom Water continues to flow after releasing button Cause of Defect 1 Particles may build up to cause jam 2 Ware and tear from normal use 3 May not...

Страница 47: ...isture on the PCB 12 8 Touch Sensor Defect Symptom 1 Does not work from initial installation 2 Does not work after some use Cause of Defect 1 Wire connection came loose 2 Got wet during operation or r...

Страница 48: ...When drain water switch is ON unit will not operate 12 9 Ice Water Full LED Blinking Symptom For new installations if the drain switch is turned on it will not operate and cause the LED to blink and c...

Страница 49: ...ver OLC S may be ex posed to light causing the sensor to malfunction 12 10 A OLC S Sensor Defect Symptom Full LED blinking Cause of Defect Light interferes with the OLC S causing it to send a wrong si...

Страница 50: ...water continues to be supplied when water tank is full Cause of Defect 1 The elasticity of the inner cap can get deformed from continuous use over a long period of time 2 In some cases particles from...

Страница 51: ...ge SH Filter Bracket How to Diagnose When OLC S and Supply Sol V V are function ing properly but water is still overflowing need to check S H Filter Bracket When OLC S and Supply Sol V V are function...

Страница 52: ...40 3 23 34 5 86 8 3 149 2 6 32 27 6 95 6 9 158 2 2 F K F K F K 22 885 41 127 104 26 6 13 652 50 99 5 113 21 8 4 485 59 78 5 122 18 5 364 68 62 5 131 14 9 14 276 77 50 140 12 4 23 211 86 40 3 149 10 4...

Страница 53: ...109 4 14 5 7 6 109 4 113 15 5 5 8 113 114 8 16 5 4 114 8 116 6 17 0 2 2 116 6 118 4 17 0 2 2 118 4 17 0 2 2 3 5 min 15 min 6 min 15 min Temp of Ice Dispensing 41 F Min Time of Ice Dispensing 60 Sec T...

Страница 54: ...54 13 Exploded Diagram Parts List 13 1 EXPLODED DIAGRAM 1...

Страница 55: ...13 2 EXPLODED DIAGRAM 2 55 Exploded Diagram...

Страница 56: ...13 3 EXPLODED DIAGRAM 3 Exploded Diagram 56...

Страница 57: ...ispensing SOL V V 1 EGI 1 2t 65 TUBE Hot Water SOL V V In 1 SILICONE 22 Solenoid DOOR 1 66 TUBE Hot Water Air Vent In 1 SILICONE 23 LLDPE Tubing 0 6 LLDPE 67 TUBE Ambient SOL V V In 1 ELASTOMER 24 PIP...

Страница 58: ...ChungHo USA 1240 N Simon Circle Suite A Anaheim CA 92806 888 758 1234 www chunghousa com techsupport chunghousa com...

Отзывы: