Trouble
Shooting
31
Connect Test Board for testing.
Each cold water process takes 60 min. Repeat 3 times; if defective, Test Board LED16 will
start blinking.
-> Ice Full LED will start blinking
12-1-F. TRC SENSOR DEFECT
Symptom
Comp. is working properly, but TRC sensor is defective, preventing Ice making.
Compressor will continue to operate until 40F.
Cause of Defect
If TRC Sensor is defective, but Comp. is operating for more than 60 min., Ice Full LED will blink
AS Procedure
1) Check to see if the wires are connected properly to the PCB.
2) If disconnected, connect properly.
3. If there is no current, replace sensor.
How to Diagnose
1
** Conduct current test.