Chuango H4 Скачать руководство пользователя страница 7

09

10

Door/Window Contact

Door/window contact is for detection of the opening-closing state. If the system is set 
to Arm and the transmitter is more than 2cm apart from the magnet, the panel will 
receive an alarm signal from door/window contact and then sound the alarm.

 

AAA 1.5V

AAA 1.5V

2.5m

Transmitter

Magnet

Indicator Light

Tamper Switch

Note:

 

Indicator light flashes once: Door/window contact is triggered. 

Flashes once after 2 seconds when triggered: The battery is running low. Please replace the 

battery as soon as possible. 

After pressing the Tamper Switch, the system will immediately sound the alarm.

Important!

Door/window Status Alert: When arm/ home arm the system without door/window 
closed, the panel will sound “DiDi” to remind you for 15s. If press the Arm button 
again, the sound will stop and system arm immediately.

PIR Motion Detector

PIR motion detector adopts digital dual-core fuzzy logic control processing technology 
and an intelligent analysis algorithm. Upon detection of human body movement, the 
panel will receive an alarm signal and then sound the alarm.

 

AAA 1.5V

AAA 1.5V

2.5m

Detection Window

Indicator Light

Note:

 

Indicator light flashes once: Motion is detected. 

Flashes three times per second: The battery is running low. Please replace the battery as soon 

as possible.

Working Mode

Testing Mode

After removing the insulating strip, the PIR motion detector will conduct a 
self-inspection for around 1 minute and then enter testing mode. The detector carries 
out detection every 10 seconds. After 3 minutes, the status indicator blinks twice, and 
the detector switches to power saving mode. 

Note:

 

Equipped with the batteries with pressing and holding the test button, the motion 

detector will remain in the testing mode eternally. That is detecting every 10 seconds. 

Reloading the batteries can exit this mode.

Power Saving Mode (Default Setting)

This product is designed with an intelligent power-saving mode. If human body 
movements are detected twice within 3 minutes, it will be automatically switched to 
sleeping mode to save power. Any movement within the detection zone will not turn 
the light on or send an alarm signal. If no human body movements have been detected 
after 3 minutes, the PIR motion detector automatically returns to the alert mode.

After self-inspection and a 3-minute testing 

mode, detector enters power saving mode

If human body movements are detected twice within 

3 minutes, the detector will automatically be switched 

to sleeping mode.

No detection of human body movement for 3 minutes

Exit sleeping mode and enter 

operating mode.

Tamper Switch

Test Button

Содержание H4

Страница 1: ...Printed in China PA H4 UM EN V1 0 H4 GSM WiFi Smart Home System User Manual ...

Страница 2: ...08 Door Window Contact 09 PIR motion detector 09 Smart Switch 11 Accessory Pairing Removal 11 12 Pairing Wireless Accessories 11 Pairing Wireless siren requires separate purchase 12 Removal of Wireless Accessories 12 Removal of Wireless Siren requires separate purchase 12 Installation of Accessories 13 14 Installation of Door Window Contact 13 Installation of PIR Motion Detector 14 App Setting and...

Страница 3: ...event malicious damage Built in 1 000 000 RF codes 105 dB siren deterrence 4 User friendliness Addition and removal of accessories by category App remote control alarm system and home appliance switch control Packaging List Please check if the following items are contained in the package In case of any missing parts please contact the distributor retailer H4 panel 1 H4 PW smart switch 1 RC 86 bidi...

Страница 4: ...n the alarm on after the designated period of time once triggered This usually applies to the door window contact of the entrance door For example if door window contact of entrance door is set as delay zone and the delay time is 30 seconds the user will be reminded with a warning sound from the panel to set the system to Disarm mode after entering the home under the Arm condition If panel has not...

Страница 5: ...y once per second GPRS network searching Flash slowly once every 3 seconds GPRS network connected Off No SIM card Note After pressing the SOS button the panel will immediately sound the alarm Tamper Switch SIM Card Slot AC Adapter Port Power Switch Pairing Button Back Side Note After pressing the Tamper Switch the panel will immediately sound the alarm Powering on the Panel Connect AC adapter to p...

Страница 6: ...at least 3 seconds the indicator light goes on The system will be set to Mute Arm Press Disarm button and the panel will make a Di sound twice setting the system to Disarm Press Disarm button for at least 3 seconds the indicator light goes on The system will be set to Mute Disarm Press Home Arm button and the panel will make a Di sound once setting the system to Home Arm Under this condition home ...

Страница 7: ...ree times per second The battery is running low Please replace the battery as soon as possible Working Mode Testing Mode After removing the insulating strip the PIR motion detector will conduct a self inspection for around 1 minute and then enter testing mode The detector carries out detection every 10 seconds After 3 minutes the status indicator blinks twice and the detector switches to power sav...

Страница 8: ...the panel makes a Di sound once that means successful pairing if the panel makes a Di sound twice that means repeated pairing Press any button on the remote control Separate the transmitter from the magnet by at least 2 cm Place the PIR motion detector in a high position and then walk within the detection area to trigger the PIR alarm once the indicator light flashes once Press and hold the Pairin...

Страница 9: ...ce objects that easily swing should not face any source of cold or heat such as a heater air conditioner refrigerator or microwave oven avoid installing two PIR motion detectors within the same detection area to prevent mutual interference 2 2 2 5m ON Step 1 Choose a Suitable Place For best detection it is recommended that you use a piece of 3M double sided adhesive tape inside the package to moun...

Страница 10: ...ight will flash quickly once per second means it enters network configuration mode 2 Open App tap Network Configuration and then follow the instruction in the app When the WiFi indicator light is steady on means wifi network connected H4 Smarthome Note In case of any change of the router name or password please set up the network configuration again User may choose GPRS network control system with...

Страница 11: ...n off select image rename and set time switch etc Rule Settings Rule settings refer to activating the whole set of smart switch modes according to different scenarios When the panel is set to Arm Disarm Home Arm or Alarm the switches with preset rules will automatically turn on off accordingly Switches without preset rules will remain unchanged Scenario for Arming Tap If Panel is Set to Arm and th...

Страница 12: ...erface below the user will receive an alarm call in case of emergency Internal Siren Setup 1 The arm disarm tone of the internal siren can be turned off by slipping the switch on the App 2 Tap Internal siren volume to choose the alarm volume level mute low medium and high The default setting is high 3 Tap Internal Siren Ringing Time to set internal siren alarming duration from 1 to 9 minutes Defau...

Страница 13: ...e required to set APN first to enable the GPRS function so if the GPRS function of the SIM card in H4 doesn t work Do as follow 1 Make sure the control panel not connect with WiFi before this APN setup or you can power up the control panel only by battery 2 Send APN to the SIM card in the control panel you ll get a message back Forward and fill in related APN username and password then send it bac...

Страница 14: ...Problems Causes Solutions Unable to turn on the panel Ensure proper connection of the power line Ensure the power adapter is transmitting electricity Insertion of SIM card into the panel shows no response Confirm that it is a GSM SIM card Ensure the SIM card is inserted in the correct direction Confirm that the card has been inserted before switching on the panel Confirm that the SIM card can disp...

Страница 15: ...A LR6 batteries which last approximately 2 years if it was set to power saving mode Specification Panel Model H4 Power Supply DC 12V 500mA Built in Battery 3 7 V 800 mAh Lithium Battery BL 5B GSM Operating Frequency 850 900 1800 1900 MHz WiFi IEEE 802 11b g n Standby Current 100 mA Alarm Current 300 mA Internal Siren Volume 105 dB Max No of Connectable Wireless Accessories 10 Remote Controls 40 De...

Страница 16: ...rea 8 m 110 Transmitting Distance 80m Open Area without Interference Wireless Radio Frequency 868 MHz or 915 MHz Bidirectional Casing Materials ABS Plastics Operating Conditions Temperature 0 C 55 C Relative Humidity 80 No Condensation Size of Detector L x W x H 117 5 x 61 x 55 mm Size of Stand L x W x H 64 x 39 x 12 mm Smart Switch Model H4 PW AC Input Input Range AC 100 240 V 50 60 Hz Maximum Lo...

Страница 17: ... place or use the alarm system in a dusty or dirty environment in order to prevent any damage being caused to its electronic components 4 Keep the alarm system out of areas with extreme heat High temperature will shorten the useful life of electronic equipment damage batteries as well as cause melting and deformation of some plastic components 5 Avoid placing the alarm system in an environment wit...

Страница 18: ...ware and software mentioned in this manual at any time without prior announcement Without the prior written authorization of smanos you shall not copy transfer or record any part of this manual save it in any searchable system or translate it into any language Smanos shall not accept liability for maloperations or malfunctions of the panel or accessories nor for damage caused by data corruption or...

Страница 19: ...部 件 名 称 说明书 材 料 80 克书写纸 工 艺 骑马钉 印 刷 尺 寸 258x185 设 计 林寿 成 品 尺 寸 129x185 注 双面四色印刷 36P ...

Отзывы: