![Chuango H4 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/chuango/h4/h4_user-manual_2606294004.webp)
03
04
Operating Principle
PIR motion detector after pairing
Door/window contact after pairing
Intrusion
detected
Panel alarm/
App notification/
phone call
Manage through remote
control/mobile phone
User
Operating Principle of Panel Alarm
Categories of Detector Zones
Normal Zone:
If panel is set to Arm or Home arm, normal zone detector will enter
operating mode. Any detection of intruders or an emergency situation will trigger the
panel alarm.
Home Zone:
If panel is set to Arm, home zone detector will enter operating mode.
Any detection of intruders will trigger the panel alarm. If panel is set to Home Arm, no
alarm signal sent from the home zone detector will be processed.
Delay Zone:
This is the alarm delay zone. If panel is set to Arm, delay zone detector
will turn the alarm on after the designated period of time once triggered. This usually
applies to the door/window contact of the entrance door. For example, if door/window
contact of entrance door is set as delay zone and the delay time is 30 seconds, the
user will be reminded with a warning sound from the panel to set the system to Disarm
mode after entering the home under the Arm condition. If panel has not been set to
Disarm after 30 seconds, it will sound the alarm.
24-Hour Zone:
24-hour zone operates independently of the setting of Arm or Disarm.
Once the zone is triggered, the alarm will be immediately activated.
Categories
Factory Default Zone
PIR-860 PIR Motion Detectorr
Home Zone (Modifiable via App)
DWC-86 Door/Window Contact
Normal Zone (Modifiable via App)
Operating together with Multiple Smart Switches
Lamp
TV
Fan
Microwave oven
Coffee machine
H4 Panel
Home appliance
switches can be
freely controlled
through App.
Operating Principle of Home Appliance Control